Texas Instruments SPRU938B manual Status Register Stat Field Descriptions

Models: SPRU938B

1 48
Download 48 pages 58.6 Kb
Page 28
Image 28

www.ti.com

VLYNQ Port Registers

3.3Status Register (STAT)

The status register (STAT) is used to detect conditions that may be of interest to the system designer. The STAT is shown in Figure 11 and described in Table 8.

Figure 11. Status Register (STAT)

31

28

27

24

23

20

19

15

Reserved

SWIDTHIN

SWIDTHOUT

Reserved

 

R-0

 

R-0

 

R-0

 

R-0

14

 

 

12

11

10

9

8

 

RXCURRENTSAMPLE

 

RTM

IFLOW

OFLOW

RERROR

 

 

R-0

 

R-1

R-0

R-0

W1C-0

7

6

5

4

3

2

1

0

LERROR

NFEMPTY3

NFEMPTY2

NFEMPTY1

NFEMPTY0

SPEND

MPEND

LINK

W1C-0

R-0

R-0

R-0

R-0

R-0

R-0

R-0

LEGEND: R/W = Read/Write; R = Read only; W1C = Write 1 to clear bit; -n= value after reset; x= reset value is indeterminate

Table 8. Status Register (STAT) Field Descriptions

Bit

Field

Value

Description

31-28

Reserved

0

Reserved. Always read as 0. Writes have no effect.

27-24

SWIDTHIN

0-Fh

Size of the inbound serial data. Indicates the number of receive pins that are being used to

 

 

establish the serial interface.

 

 

 

 

 

0

No pins used

 

 

1h

1

RX pin used

 

 

2h

2

RX pins used

 

 

3h

3

RX pins used

 

 

4h

4

RX pins used

 

 

5h-Fh

Reserved

23-20

SWIDTHOUT

0-Fh

Size of the outbound serial data. Indicates the number of transmit pins that are being used

 

 

 

to establish the serial interface.

 

 

0

No pins used

 

 

1h

1

TX pin used

 

 

2h

2

TX pins used

 

 

3h

3

TX pins used

 

 

4h

4

TX pins used

 

 

5h-Fh

Reserved

19-15

Reserved

0

Reserved. Always read as 0. Writes have no effect.

14-12

RXCURRENTSAMPLE

0-Fh

Current RTM sample. Indicates the current clock sample value used by RTM.

11

RTM

1

RTM enable. Always read as 1. Indicates that the VLYNQ module on the DM643x DMSoC

 

 

 

has the receive timing manager (RTM).

10 IFLOW

0

1

9 OFLOW

0

1

Inbound flow control.

Free to transmit.

Indicates that a flow control enable request has been received and has stalled transmit until a flow control disable request is received.

Outbound flow control. Indicates the status of the two inbound FIFOs (FIFO1 or FIFO2). Indicates that the internal flow control threshold is not yet reached.

Indicates that the internal flow control threshold has been reached (FIFO1 or FIFO2 is full) and a flow control enable request has been sent to the remote device.

28

VLYNQ Port

SPRU938B –September 2007

 

 

Submit Documentation Feedback

Page 28
Image 28
Texas Instruments SPRU938B manual Status Register Stat Field Descriptions