VLYNQ Port Registers

3.2Control Register (CTRL)

The control register (CTRL) determines operation of the VLYNQ module. The CTRL is shown in Figure 10 and described in Table 7.

Figure 10. Control Register (CTRL)

31

30

29

27

26

24

 

23

22

 

21

20

19

 

18

16

PMEN

SCLKPUDIS

Reserved

RXSAMPELVAL

RTMVALIDWR RTMENABLE

TXFASTPATH

Reserved

CLKDIV

R/W- 0

R/W- 0

R-0

 

R/W- 3h

R/W- 0

R/W- 0

 

R/W- 0

R-0

 

R/W- 0

15

14

 

13

 

12

8

7

6

3

2

 

 

 

1

0

CLKDIR

INTLOCAL

INTENABLE

INTVEC

 

INT2CFG

Reserved

AOPTDISABLE

 

ILOOP

RESET

R/W- 0

R/W- 0

 

R/W- 0

 

R/W-0

 

R/W-0

R-0

 

R/W- 0

 

R/W- 0

R/W- 0

LEGEND: R/W = Read/Write; R = Read only; -n= value after reset

 

 

 

 

 

 

 

 

 

 

Table 7. Control Register (CTRL) Field Descriptions

Bit Field

Value Description

31 PMEN

0

1

Power management enable.

VLYNQ CLK is always active if it is set as an output (assuming that VLYNQ module is enabled).

If set as an output, VLYNQ CLK becomes inactive when there is no traffic over the serial bus.

The PMEN bit should only be set to 1 when the SCRUN is connected to the remote/external VLYNQ device.

30

SCLKPUDIS

0

Serial clock pull-up disable. Always write 0.

29-27

Reserved

0

Reserved. Always read as 0. Writes have no effect.

26-24

RXSAMPELVAL

0-7h

RTM sample value. If the RTMENABLE bit is 0, the receive timing manager forces the value in the

 

 

 

RXSAMPELVAL bit as the clock sample value. If the RTMENABLE bit is 1, then the value set by

 

 

 

the RXSAMPELVAL bit is ignored. In order to modify the value, you must simultaneously write a 1

 

 

 

to the RTMVALIDWR bit.

23

RTMVALIDWR

 

RTM valid write bit.

 

 

0

Will not allow writes to RXSAMPLEVAL bits.

 

 

1

Will allow writes to RXSAMPLEVAL bits.

22

RTMENABLE

 

RTM enable bit.

 

 

0

The receive timing manager uses the value set in the RXSAMPLEVAL bit as the clock sample

 

 

value.

 

 

 

 

 

1

The receive timing manager is enabled. It automatically selects the receive clock.

21

TXFASTPATH

0-1

Transmit fast path. When set, the fastest path is chosen for the serial data.

20-19

Reserved

0

Reserved. Always read as 0. Writes have no effect.

18-16

CLKDIV

0-7h

Serial clock output divider.

15

CLKDIR

 

Serial CLK direction. Determines whether the VLYNQ CLK is an input or an output.

 

 

0

The VLYNQ CLK is externally sourced.

 

 

1

The VLYNQ CLK is internally sourced and equal to the VLYNQ module system clock divided by the

 

 

divider value set in the CLKDIV bit.

 

 

 

14

INTLOCAL

 

Interrupt local.

 

 

0

The interrupt is forwarded to the remote VLYNQ device over the serial interface as an interrupt

 

 

 

packet.

1

13 INTENABLE

0

1

12-8 INTVEC

0-1Fh

Interrupt is posted in the interrupt status/clear register and results in the assertion of the VLQINT to the device interrupt controllers.

Interrupt enable.

VLYNQ module status interrupts are ignored.

VLYNQ module status interrupts (if RERROR or LERROR bits are set) are posted to the interrupt pending/set register.

Interrupt vector. This bit indicates which bit in the interrupt pending/set register is set for VLYNQ module status (RERROR/LERROR) interrupts.

26

VLYNQ Port

SPRU938B –September 2007

Submit Documentation Feedback

Page 26
Image 26
Texas Instruments SPRU938B manual Control Register Ctrl Field Descriptions