Thermador SGSCV36G, SGS30/36G Cooknvent Ventilator, Care, To Remove the Filters Clean the Panel

Models: GGS30/36/365 GGSCV30/36/365 SGS30/36G SGSCV36G

1 96
Download 96 pages 14.14 Kb
Page 28
Image 28

COOK'N'VENT_ VENTILATOR

See "SAFETY PRACTICES,"

on Page 4.

The efficiency of the exhaust system depends on the cleanliness of the ventilator, especially the filters. The frequency of cleaning depends on

the amount and type of cooking pre- formed.

CARE*

Scrape

Grease Off

Section Five: Care & Maintenance

Side Supports

Hook over Side

FILTERS and INTAKE

PANEL

Filters become soiled in a short pe- riod of time and should be cleaned

regularly. The filters may be cleaned by agitating them in a hot detergent

solution or by washing in the dish- washer.

Do not use the ventilating system ]

without the filters place.

TO REMOVE THE FILTERS

AND CLEAN THE PANEL

ix_'---r-

il 7-114 II

Raise the Vent to its

Maximum Height

. Raise the ventilator intake to its

maximum height. If the blower is on, turn it off.

Ventilator

Ca.

//, i17 Panel

. Grasp the front panel at the top

towards the sides and pull up

and forward: remove and set aside.

. Using a nylon or other soft-touch

spatula, lift the accumulated

grease from the back panel - be- hind the filters. Clean front and

back panels using a mild grease solvent (See Cleaning Chart for Stainless Steel).

 

after each

use.

 

J

 

TIP: Wipe

the intake off

TO

REPLACE

THE

FILTERS

 

AND

THE FRONT

PANEL

 

Place Filters side by side

. Place the filters side by side on the support bars in front of the back panel. They will lean for- ward and the tops will rest against the inside of the front panel supports.

. Replace ventilator cap. Be cer-

tain all sides of the cap fit inside

the ventilator sides and back

panel.

Supports

. Hook the top of the front intake panel over the side supports at the top of the ventilator.

Cover and Vent Going Down

10.As the ventilator intake is low- ered, the cover will return to its position covering the ventilator.

To Clean Gap Area

Between Ventilator &

Cooktop

1.With ventilator in up position, remove front panel, ventilator cap and filters.

2.Lower ventilator completely.

3.Clean gap area using a mild

grease solvent (see Cleaning Chart).

4.Raise ventilator completely and replace filters, cap and front panel.

.

Remove

the ventilator

cap by

 

 

 

 

 

 

grasping

both ends of the cap

.

Replace

the front panel by

hook-

 

and

lifting

up.

 

 

ing

the

lower front edge

of the

 

 

 

 

 

 

front panel over the lower front

4. Lift

out the filters and

clean.

 

edge

of

the ventilator.

 

* Not on all Models.

Page 26

Page 28
Image 28
Thermador SGSCV36G, SGS30/36G, GGSCV30/36/365 owner manual Cooknvent Ventilator, Care, To Remove the Filters Clean the Panel