Windsor CS24 10060210 manual 3-19, Machine Operation, Emptying And Cleaning Tanks, Recovery Tank

Models: CSXE24 10060290 CS24SP 10060220 CSX24 10060270 CSE24 10060250 CS24 10060210 CSE24SP 10060260 CSXEO24 10060300

1 61
Download 61 pages 38.1 Kb
Page 26
Image 26
EMPTYING AND CLEANING TANKS

MACHINE OPERATION

SOLUTION

DRAIN HOSE

RECOVERY

DRAIN HOSE

EMPTYING AND CLEANING TANKS

1.Park the machine next to a floor drain. Drain hoses are at the front of the machine.

2.Turn the machine power off.

RECOVERY TANK

1.Pull the large drain hose from under the front of the tank. Unscrew cap, then lower hose in direction of the drain. Do not stand in front of end of hose. Recovered solution will come out with force.

2.Remove the recovery tank dome. Flush the recovery bag out with clean water. Do not use water hotter than 140°F (60°C) to clean tank. Damage may occur.

3.Clean debris from dome basket.

4.Clean off the float shut-off system and inspect for free movement of float. The float shut-off system is located in the rear of the recovery tank.

5.Replace the drain cap and secure drain hose under tank.

6.If machine is to be stored, leave the recovery tank dome off.

SOLUTION TANK

1.Pull recovery drain hose out to expose the solution drain hose.

2.Pull the solution drain hose from under front of the tank. Unscrew the T-handle on plug enough to loosen plug, then lower hose in direction of drain. Slowly remove plug from drain hose.

3.Remove the solution tank cover.

4.Flush the solution tank out with clean water and run several gallons of clean water through systems. Do not use water hotter than 140°F (60°C) to clean tank. Damage may occur.

NOTE: Never allow solution to remain in tank. Damage to tank, seals and valves could occur.

Tuck drain hose under tank and secure with recovery drain hose by tucking it under tank.

3-19

86037660 CHARIOT 11/09/06

Page 26
Image 26
Windsor CS24 10060210, CSE24 10060250 3-19, Machine Operation, Emptying And Cleaning Tanks, Recovery Tank, Solution Tank