4-30

MACHINE TROUBLESHOOTING

 

 

ERROR

 

PROBLEM

CAUSE

CODE

SOLUTION

 

 

DELUXE

 

Vacuum motor does not run, or

Circuit breaker tripped (Basic)

 

Reset circuit breaker

runs slowly

 

 

 

Faulty vacuum circuit or switch

7700

Check wires, connections

 

 

 

 

and switch

 

Worn vacuum motor brushes

 

Replace brushes, check

 

 

 

commutator

Squeegee will not go up/down

Faulty circuit or actuator

 

Check wires, connectors

 

(Deluxe)

 

and actuator

 

Faulty cables or pulleys

 

Repair/replace cables or

 

 

 

pulleys

Poor scrubbing performance

Debris caught in scrub brushes

 

Remove debris

 

 

 

 

 

Worn brushes or pads

 

Replace brushes or pads

 

 

 

 

 

Improper detergent, brush or

 

Contact equipment or

 

pad used

 

application specialists

 

Low scrub brush down pressure

 

Increase brush pressure

 

 

 

 

 

Low battery charge

 

Charge batteries

 

 

 

 

Little or no solution flow to the floor

Solution tank empty

 

Fill solution tank

 

 

 

 

 

Solution flow turned off or set

 

Turn on or increase flow

 

too low

 

setting

 

Solution strainer plugged

 

Clean solution strainer

 

 

 

 

 

Solution system plumbing

 

Clear obstruction from

 

obstructed

 

plumbing

 

Pump obstructed

 

Clean or replace pump

 

 

 

 

 

Solution solenoid valve

 

Clean or replace valve

 

obstructed or stuck

 

 

 

Solution shut-off valve is closed

 

Open shut-off valve

 

 

 

 

 

Faulty pump circuit or pump

 

Check wiring, connections,

 

 

 

control broad (Basic) and

 

 

 

pump.

 

Faulty solenoid

 

Check solenoid valve

 

 

 

 

Brush motors do not run, or run

Circuit breaker(s) tripped

7600

Reset circuit beaker(s)

slowly

 

 

 

Low battery charge

 

Charge battery

 

 

 

 

 

 

 

Fault brush circuit or motor

7600

Check wires, connections

 

 

 

and motor

 

Worn brush motor brushes

 

Replace brushes, check

 

 

 

commutator

Scrub deck will not go down/up

Actuator circuit breaker tripped

 

Reset breaker

 

(Basic)

 

 

 

Faulty actuator circuit or

 

Check wires, connections

 

actuator

 

and actuator

Scrub deck goes down, then raises

No brushes or pad drivers on

9000

Install brushes or pad

 

machine

 

drivers

Error code not listed is displayed

Controller detects electrical

 

Contact service technician

 

problem

 

 

86037660 CHARIOT 01/03/08

4-30

Page 57
Image 57
Windsor CSXE24 10060290, CSE24 10060250 manual 4-30, Machine Troubleshooting, Error, Problem, Cause, Code, Solution, Deluxe