Windsor CSXE24 10060290 Vacuum Motor Carbon Brushes, 4-23, Maintenance-Vacuum& Float Shut-Off

Models: CSXE24 10060290 CS24SP 10060220 CSX24 10060270 CSE24 10060250 CS24 10060210 CSE24SP 10060260 CSXEO24 10060300

1 61
Download 61 pages 38.1 Kb
Page 50
Image 50
RECOVERY TANK FLOAT SHUT-OFF

MAINTENANCE-VACUUM & FLOAT SHUT-OFF

RECOVERY TANK FLOAT SHUT-OFF

When water is no longer being vacuumed from the floor and the vacuum fan is operating, the ball float has engaged. The vacuum motor will not vacuum water with recovery tank full. The recovery tank must be drained.

1.The float shut-off screen can be cleaned in or out of the machine.

2.To clean the float shut-off while it is inside the machine wipe material off screen then rinse. Check that the ball is also clean and moves freely.

3.To remove the float shut-off, grasp the screen with one hand and the connected tube with the other. Tilt and pull the float screen assembly to pull it off the barb on the tube.

4.To install, place one hand on the tube, and then tilt and push the float screen assembly over the barb on the tube.

FOR SAFETY: before leaving or servicing machine, stop on a level surface, turn off machine and disconnect power.

TO REPAIR OR REPLACE VACUUM MOTOR

1.Remove rear cover from machine.

2.Remove two screws from top of control panel and four screws from sides of control housing.

3.Slide control housing back from tank to expose vacuum motor.

4.Disconnect electrical connector from the vacuum motor.

5.Remove three nuts that secure vacuum motor retaining plate, remove plate and vacuum motor.

6.Reverse steps to install. Make sure that gasket is on vacuum so that vacuum seals against tank

Vacuum Motor Carbon Brushes

TO REPAIR OR REPLACE VACUUM MOTOR End Cap

Carbon

Brushes

If armature commutator is grooved, extremely pitted or not concentric, the motor will need to be replaced or sent to a qualified service center.

Important:

These brushes wear quicker as the length shortens due to increased heat. Spring inside brush housing will damage motor if brushes are allowed to wear away completely.

Vacuum Motor Carbon Brushes 38 [9.5mm]

Periodically check the length of the carbon brushes. Replace both carbon brushes when either is less than 3/8" (9.5mm) long.

4-23

86037660 CHARIOT 11/09/06

Page 50
Image 50
Windsor CSXE24 10060290, CSE24 10060250 manual Vacuum Motor Carbon Brushes, 4-23, Maintenance-Vacuum& Float Shut-Off