MAINTENANCE-SOLUTION STRAINER & PUMP

MAINTENANCE-SOLUTION STRAINER & PUMP

1. SOLUTION STRAINER-COARSE

3. PUMP

Located in bottom of tank. The coarse strainer protects the finer strainer from large debris. If the fine strainer is clean and the pump and solenoid valve are not working, then check the coarse strainer for debris. Drain the solution tank and clean the coarse strainer. To remove the strainer, rotate the strainer counterclockwise. Cleanout the debris from wire mesh and re-assemble.

2.SOLUTION STRAINER (FINE) AND SHUT-OFF VALVE

The fine strainer is located in front left corner of machine on disk models and in right rear corner of cylindrical models. The fine strainer protects the pump and solenoid valve from debris. If there is little or no solution flow to the ground, first check to make sue the shut-off valve is open. Next, check the strainer for debris. To remove the strainer, first turn the shut-off valve to the off position. Then, turn the bottom part of the strainer counterclockwise until the bottom is separated. Clean out the debris from the wire mesh and re-assemble. Make sure the O-ring gasket is in place when re-assembled. To resume flow, turn the shut-off valve to the open position.

The pump is located under the tank on the right side of machine. The pump delivers solution from the tank to the scrub deck.

To repair or replace pump:

1.Remove scrub deck skirts, Aqua-Mizer, and squeegee from machine.

2.Lower scrub deck to gain access to pump mounting plate.

3.Remove screw that secures pump mounting plate to frame.

4.The pump is located under the tank on the right side of machine. The pump delivers solution from the tank to the scrub deck. Pull pump mounting plate forward and down to expose pump.

5.Reverse steps to install.

4.PUMP MOUNTING PLATE

See graphic representation on previous page.

5.SOLENOID VALVE

The solenoid valve is mounted on the front of the scrub deck, on left side.

The solenoid valve shuts off solution flow to scrub deck whenever scrubbing stops. To repair or replace solenoid valve, cut cable ties that secure it to deck.

 

 

 

 

PUMP HEAD REPLACEMENT

VALVE ASM.

DIAPHRAGM ASM.

 

(86136450)

(86137240)

(86235090)

 

(PRV NO. 65151)

(PRV NO. 84145)

(PRV NO. 29188)

 

 

 

 

 

4-21