MAINTENANCE-SOLUTION STRAINER & PUMP
1. SOLUTION | 3. PUMP |
Located in bottom of tank. The coarse strainer protects the finer strainer from large debris. If the fine strainer is clean and the pump and solenoid valve are not working, then check the coarse strainer for debris. Drain the solution tank and clean the coarse strainer. To remove the strainer, rotate the strainer counterclockwise. Cleanout the debris from wire mesh and
2.SOLUTION STRAINER (FINE) AND SHUT-OFF VALVE
The fine strainer is located in front left corner of machine on disk models and in right rear corner of cylindrical models. The fine strainer protects the pump and solenoid valve from debris. If there is little or no solution flow to the ground, first check to make sue the
The pump is located under the tank on the right side of machine. The pump delivers solution from the tank to the scrub deck.
To repair or replace pump:
1.Remove scrub deck skirts,
2.Lower scrub deck to gain access to pump mounting plate.
3.Remove screw that secures pump mounting plate to frame.
4.The pump is located under the tank on the right side of machine. The pump delivers solution from the tank to the scrub deck. Pull pump mounting plate forward and down to expose pump.
5.Reverse steps to install.
4.PUMP MOUNTING PLATE
See graphic representation on previous page.
5.SOLENOID VALVE
The solenoid valve is mounted on the front of the scrub deck, on left side.
The solenoid valve shuts off solution flow to scrub deck whenever scrubbing stops. To repair or replace solenoid valve, cut cable ties that secure it to deck.
|
|
|
|
PUMP HEAD REPLACEMENT | VALVE ASM. | DIAPHRAGM ASM. |
|
(86136450) | (86137240) | (86235090) |
|
(PRV NO. 65151) | (PRV NO. 84145) | (PRV NO. 29188) |
|
|
|
|
|