MACHINE TROUBLESHOOTING – DELUXE CONTROLLER FAULT CODES

ERROR

 

 

CODE

 

 

DELUXE

PROBLEM

SOLUTION

 

 

Disconnect batteries and wait 1 minute before

None

LCD display on, but incomplete

re-applying power.

 

 

Disconnect batteries and wait 1 minute before

0A01

Power down error

re-applying power.

0204

Memory corrupt

Replace controller.

 

 

Check for short or open circuits in throttle

All 080_ codes

Throttle wiring

wiring.

 

 

Check for short circuit between B+ and

All 140 _ Codes

 

traction output.

 

Possible short circuit of motors, auxiliary

Check for short circuits. If code is present

 

outputs (headlight, recycle pump, or back-

after short circuits are repaired, replace

All 310_ Codes

up alarm), wiring or damaged controller

controller.

 

 

Wiring fault on 6-way serial link between

7500

LCD module communications timeout

controller and display.

 

 

Disconnect batteries and wait 1 minute before

7501

LCD module settings corrupt

re-applying power.

 

 

Check for short or open circuits in brush

All 760_ Codes

Brush motor or brush circuit fault

motors or wiring.

 

 

Check for short or open circuits in vacuum

All 770_ Codes

Vacuum motor or vacuum circuit fault

motor(s) or wiring.

 

 

Check for open circuit on propel motor or

7800

Traction motor open circuit fault

wiring.

 

 

Check for short circuit on propel motor or

7801

Traction motor overcurrent error

wiring.

 

 

Propel motor current has exceeded current

7802

Traction motor in power foldback state

limit for the foldback time.

All 790_ Codes

Emergency stop error

E-stop input active or wiring fault.

 

 

Check that brushes or pads are installed.

 

 

Check for open circuit in scrub lift actuator,

9000

Brush current requirement not satisfied

circuit breaker or wiring.

4-31

86037660 CHARIOT 05/27/08

Page 58
Image 58