Windsor CSE24SP 10060260 Scrub Controls-Deluxe, One Touch Switch, Vacuum/Squeegee Switch, 3-11

Models: CSXE24 10060290 CS24SP 10060220 CSX24 10060270 CSE24 10060250 CS24 10060210 CSE24SP 10060260 CSXEO24 10060300

1 61
Download 61 pages 38.1 Kb
Page 18
Image 18
SCRUB CONTROLS-DELUXE

SCRUB CONTROLS-DELUXE

5

One Touch Switch 1

4 3 2

1.

One Touch Switch

4.

Vacuum/Squeegee Switch

2.

Solution Control Switch

5.

Display Toggle Switch

3.Brush Pressure Switch

1.ONE TOUCH SWITCH

This switch controls the scrub brushes and vacuum all in one touch.

To start scrubbing, press the one touch switch. The brush drive motors will turn on, the scrub deck will lower to the "light scrub" position, the solution will flow at “one bar” rate, the squeegee will lower and the vacuum will turn on. The information display window will show which functions are operating. If the throttle pedal is in the neutral position for more than two seconds the brushes and solution flow will stop. If the one touch switch is activated without brushes installed, the brush motors will stop, the scrub deck will rise, and the brush pressure indicator will display error code 9000.

To stop scrubbing, press the one touch switch. The brush drive motors will turn off, the scrub deck will raise the solution flow will stop, the squeegee will raise after a 15 second delay, and the vacuum motor will turn off. This delay is to clear the vacuum hose of recovered solution.

3-11

86037660 CHARIOT 11/09/06

Page 18
Image 18
Windsor CSE24SP 10060260 Scrub Controls-Deluxe, One Touch Switch, Vacuum/Squeegee Switch, Solution Control Switch, 3-11