Windsor CS24SP 10060220 manual 4-14, Maintenance-Scrubdeck - Cylindrical, Scrub Head-Cylindrical

Models: CSXE24 10060290 CS24SP 10060220 CSX24 10060270 CSE24 10060250 CS24 10060210 CSE24SP 10060260 CSXEO24 10060300

1 61
Download 61 pages 38.1 Kb
Page 41
Image 41

MAINTENANCE-SCRUB DECK - CYLINDRICAL

SCRUB HEAD-CYLINDRICAL

The dual cylindrical scrub head is designed to eliminate debris that may be caught in the squeegee while scrubbing. Water is applied to the first scrubbing brush turning in a clockwise rotation when viewed from the right of operator’s side of machine. The first brush scrubs dirt and debris between the brushes. The second scrubbing brush, turning in a counter clockwise rotation, picks up debris and throws it into a removable hopper. The larger debris which might catch under the squeegee is collected in the hopper. Water is allowed to drain out the hopper into the squeegee path where it is recovered from the floor.

MAINTENANCE

The brushes should wear evenly side to side if properly adjusted. Scrub brushes should be exchanged front to back every 50 hours to ensure even wear since the rear brush contacts the floor with more force. It is not necessary to rotate end for end since swapping front to back puts the brushes in the opposite rotation, as well as balancing wear. Scrub brushes should be replaced as a set when bristle length wears to height of yellow PerformAlertTM bristles.

SCRUB BRUSH REMOVAL

The scrub brushes are removed from the side of the machine. The front is removed from the right side and the rear is removed from the left side.

1.Unscrew the knob and swing side squeegee out about 90°

2.Unscrew knob on side door but do not remove.

3.Pull out on top of door until lip on door clears brush head.

4.Push down on door until hooks on bottom of door are free of scrub head side.

5.Pull out on door with a rocking motion to free idler door from end of brush.

6.Pull brush out with a rocking motion to free brush from drive hub.

SCRUB BRUSH REPLACEMENT

1.Unscrew the knob and swing side squeegee out about 90°

2.Lift the drive side of the brush. Push brush until a positive stop is felt. The idler plate cannot be installed until the brush is fully seated on the drive hub.

3.Allow brush to drop below scrub deck. Fully insert plate onto brush.

4.Line up bottom hook on idler door with notches on side of scrub head.

5.Slide idler door up until lip rests on top of scrub head.

6.Hand tighten knob to secure door into place.

TO ADJUST SCRUB DECK SIDE SQUEEGEES

These skirts should be adjusted to 3/8” deflection.

To adjust:

1.Lower scrub deck to floor.

2.Stop machine.

3.Loosen scrub deck skirt stop.

4.Adjust stop such that skirt deflection is about 3/8”.

TO REPLACE SCRUB DECK SIDE SQUEEGEES

These skirts have four wear edges.

To use another edge:

1.Remove each of the scrub deck skirt assemblies.

2.Remove the hardware that retains the blade on each assembly.

3.Flip the blade vertically or horizontally, or both, and replace hardware.

4.Re-install each scrub deck assembly.

86037660 CHARIOT 11/09/06