ACTUATOR SCRUB DECK
REMOVAL/REPLACEMENT
FOR SAFETY: Before leaving or servicing machine, stop on a level surface. Turn off machine.
1.Lower scrub deck.
2.Disconnect spring assembly from actuator slide link.
3.Remove the clevis pin retaining the top of the acutator.
4.Remove slide link and actuator as an assembly by removing the two bolts connecting them to the deck through the bushings.
5.Either unthread the actuator main lead screw from the barrel, or remove the two bolts connecting the barrel to the slide link.
6.Reverse for
SCRUB DECK ACTUATOR ADJUSTMENT
The actuator will need to be adjusted when replaced.
To adjust the actuator:
1.While holding actuator barrel to prevent it from spinning, apply power to the actuator such that it is fully extended. Positive power to white wire, and negative/ground to black. Limit switch within actuator will stop it.
2.Turn barrel out one or more full turns to assure that when it is retracted it will not bind against itself.
3.While holding actuator barrel to prevent it from spinning, apply power to the actuator such that it is fully retracted. Positive power to black wire, and negative/ground to white wire. Limit switch within actuator will stop it.
4.With actuator fully retracted, turn barrel in until it touches the base of the threaded shaft.
5.At the bottomed out position, turn the barrel out only enough to allow connection to slide link.
6.Connect actuator.
7.Check travel of actuator during operation.