Toshiba 1600XP operation manual Changeable Service Software compenents 251 Vref PhAdj

Models: 1600XP

1 100
Download 100 pages 60.45 Kb
Page 76
Image 76

B-4

1600XP Series Installation and Operation Manual

1600XP Command Parameters Table

Cmd

Description

Brief Description

Location Map

Example

Rqd Security

By

ID

on LCD

 

 

 

 

Level to change

 

 

Tab

Block

 

 

222

VOOV De-

Output Overvoltage Detection Level in percent-

Setting

OUT

110 %

Nonchangeable

User

 

Level*

age

 

 

 

Nonchangeable

Administrator

 

 

- Of rated output voltage which was configured

 

 

 

Changeable

Service

 

 

with Command ID215

 

 

 

 

 

 

 

 

 

 

 

 

 

224

Fo Syn Win-

Output Frequency Synchronization Window

Setting

OUT

1.0 Hz

Nonchangeable

User

 

dow*

 

 

 

 

Nonchangeable

Administrator

 

 

 

 

 

 

Changeable

Service

 

 

 

 

 

 

 

 

225

Fo Slew Rate

Output Frequency Slew Rate

Setting

OUT

10

Changeable

Service

 

 

 

 

 

 

 

 

226

Vout Adjust

Output Voltage Adjustment

Setting

OUT

0

Nonchangeable

User

 

 

- Can adjust up to +/- 5 increment of one in

 

 

 

Changeable

Administrator

 

 

order to increase or decrease output voltage to

 

 

 

Changeable

Service

 

 

compensate line voltage drop.

 

 

 

 

 

 

 

 

 

 

 

 

 

227

Iout 100%

Output Current 100% Amount

Setting

OUT

250

Changeable

Service

 

Amount

 

 

 

 

 

 

 

 

 

 

 

 

 

 

228

OOL Delevel

Output Overload Warning/Fault Detection Level

Setting

OUT

110

Changeable

Service

 

 

in percentage

 

 

 

 

 

 

 

 

 

 

 

 

 

229

OOL DeDelay

Output Overload Warning/Fault Detection De-

Setting

OUT

30

Changeable

Service

 

 

lay at 125% @25°

 

 

 

 

 

 

 

 

 

 

 

 

 

230

OOL ReLevel

Output Overload Warning Recovery Delay

Setting

OUT

105

Changeable

Service

 

 

 

 

 

 

 

 

231

OOL ReDelay

Output Overload Warning Recovery Delay

Setting

OUT

160

Changeable

Service

 

 

 

 

 

 

 

 

232

Vout Comp.

Output Voltage will be compensated according

Setting

OUT

20

Changeable

Service

 

Step

to this setup and current percentage

 

 

 

 

 

 

 

 

 

 

 

 

 

233

Vout Gain

Use this value to convert AD value to Actual

Setting

OUT

7987

Changeable

Service

 

 

Value

 

 

 

 

 

 

 

 

 

 

 

 

 

234

Vout Offset

Feedback Offset adjustment due to hardware

Setting

OUT

0

Changeable

Service

 

 

and software components

 

 

 

 

 

 

 

 

 

 

 

 

 

242

Iout Gain

At 240VAC use this value to convert AD VAlue

Setting

OUT

1131

Changeable

Service

 

 

to Actual Value

 

 

 

 

 

 

 

 

 

 

 

 

 

243

Iout Offset

Feedback Offset adjustment due to hardware

Setting

OUT

0

Changeable

Service

 

 

and software compenents.

 

 

 

 

 

 

 

 

 

 

 

 

 

251

Vref PhAdj

Time delay adjustment to sync the actual phase

Setting

OUT

-8

Changeable

Service

 

60Hz

of output and plotting.

 

 

 

 

 

 

 

 

 

 

 

 

 

254

Vref Amplitude

Calibrated no Load Output Voltage

Setting

OUT

246

Changeable

Service

 

 

 

 

 

 

 

 

Page 76