(1. 3) Changing each setting in E.TRG mode
The E.TRG has five modes; 1P SNR, 1P SR, PW SNR, PW SR, PR.
First set the "→" to MODE and select E. TRG, then set the "→" to E.TRG and select the desired E.TRG mode.
(1. 3. 1) Changing each setting in 1P SNR mode
Move up down By pushing
MENU UP, DOWN
Set by pushing
DATA UP, DOWN
| |
MODE | E.TRG |
E.TRG | 1P SNR |
TRG.P |
|
EXP. | 50ms |
PART | OFF |
<MODE = E.TRG E.TRG = 1P SNR>
•Sutter mode MANU, SS, E.TRG
•E.TRG mode
1P SNR, 1P SR, PW SNR, PW SR, RR
• Input trigger pulse setting at 1P SNR and 1P SR
Input trigger pulse : positive polarity Input trigger pulse : negative polarity
• Exposure time setting at 1P SNR and 1P SR
0.01 ms0.02 ms0.4 ms1 ms20 ms50 ms
0.01 ms | 0.02 ms | 0.1 ms | 1 ms | 2 ms |
step | step | step | step | step |
•Partial scanning switch OFF/25fps/30fps/35fps/40fps/45fps/50fps/ E25fps/E30fps/E35fps/E40fps/E45fps/E50fps
(a) Changing the polarity of inputting trigger pulse setting
1Set the "→" to TRG.P by pushing [MENU UP], [MENU DOWN] buttons.
2Select either , by pushing [DATA UP], [DATA DOWN] buttons.
(b) Changing 1P SNR exposure time setting
1Set the "→" to EXP. by pushing [MENU UP], [MENU DOWN] buttons.
2Set the exposure time by pushing [DATA UP], [DATA DOWN] buttons.
(c) Changing the partial scanning setting
1Set the "→" to PART by pushing [MENU UP], [MENU DOWN] buttons.
2Select the mode by pushing [DATA UP], [DATA DOWN] buttons.
15