( 4 ) PW SR (Pulse width trigger SYNC-RESET)

The trigger input to the CC1 of the DIGITAL terminal develops 1 frame images.

(4. 1) 1 Pulse Width Trigger SYNC-RESET Picture Output Timing

Negative polarity mode

Trigger*1

Positive polarity mode

About 1 s

About 7 s

 

Exposure period*2

Exposure completion

 

 

0 to 2H

(Internal VD)*3

RGB data (video interval image)

FVAL

LVAL,

DVAL

58H (Partial scanning OFF)

40H (Partial scanning 25fps)

56H (Partial scanning 30fps)

66H (Partial scanning 35fps)

78H (Partial scanning 40fps)

80H (Partial scanning 45fps)

86H (Partial scanning 50fps)

*1: Externally input signal

*2: Exposure time = Trigger pulse width + 6 s

(Valid trigger pulse width is 2 s or greater for external trigger shutter operation.)

*3: VD is generated after 0 to 2H following the completion of the exposure period and the video is synchro- nized to this and output.

Note:

When the next trigger is input before completion of the output of the video corresponding to the trig- ger, there will be an effect on the video.