( 7 ) Setting to factory setting status

All the settings can be returned to the factory default status (preset status).

(1)If characters are displayed on the screen, press the [DISP] button to disable the character display.

(2)Push [MENU DOWN] and [DATA DOWN] buttons simultaneously for approx. 1 second.

(3)The preset operation starts. When the preset operation finishes, the character PRESET OK is displayed for approx. 1 second.

7. 3 Synchro. Scan Operation

The shutter speed can be set by the double horizontal scanning period (2H) or by the frame.

( 1 ) Setting by 2H

2H/1592H ~ 1590H/1592H stands for the setting by the 2H and the shutter speed can be set by the 2H (62.8 s).

When operating Partial Scannig, the number’s listed below can be used for setting.

25fps, E25fps

2H/1270H ~ 1268H/1270H

30fps, E30fps

2H/1060H ~ 1058H/1060H

35fps, E35fps

2H/910H ~ 908H/910H

40fps, E40fps

2H/774H ~ 772H/774H

45fps, E45fps

2H/706H ~ 704H/706H

50fps, E50fps

2H/636H ~ 634H/636H

( 2 ) Setting by the frame

2FRM to 512FRM stand for the setting (long period exposure) by the frame.

The video signal stored during the frame period set is output as 1 frame video image at a frame interval specified.

(Internal VD)

RGB data (video interval image)

FVAL

LVAL,

DAVL

n

n+1

(4FRM setting)

23

Page 23
Image 23
Toshiba IK-TF9U Synchro. Scan Operation, Setting by the frame, Setting to factory setting status, Setting by 2H