( 3 ) PW SNR (Pulse width trigger SYNC-NON RESET)

The trigger input to CC1 of the DIGITAL terminal develops 1 frame images.

(3. 1) Pulse Width Trigger SYNC-NON RESET Picture Output Timing

Negative polarity mode

Trigger*1

Positive polarity mode

About 1 s

About 7 s

 

 

Exposure period*2

Exposure period*2

(Internal VD)

RGB data (video interval image)

FVAL

LVAL,

DVAL

 

58H

(Partial scanning OFF)

The internal VD falling edge is within the

 

40H

(Partial scanning 25fps)

 

exposure period and thus video is not output.*3

 

56H

(Partial scanning 30fps)

 

 

 

66H

(Partial scanning 35fps)

 

 

78H

(Partial scanning 40fps)

 

 

80H

(Partial scanning 45fps)

 

 

86H

(Partial scanning 50fps)

 

*1:

Externally input signal

 

 

*2:

Exposure time = Trigger pulse width + 6 s

 

 

(Valid trigger pulse width is 2 s or greater for external trigger shutter operation.)

*3: Video is output at the falling edge of the internal VD following completion of the exposure period. The video and FVAL/LVAL/DVAL have a paired relationship.

Note:

When the next trigger is input before completion of the output of the video corresponding to the trig- ger, there will be an effect on the video.