(1. 3. 2) Changing each setting in 1P SR mode

Move up down

Set by pushing

By pushing

DATA UP, DOWN

MENU UP, DOWN

 

-- SHUTTER --

 

MODE

E.TRG

E.TRG

1P SR

TRG.P

 

EXP.

50ms

PART

OFF

<MODE = E.TRG E.TRG = 1P SR>

Sutter mode MANU, SS, E.TRG, RR

E.TRG mode

1P SNR, 1P SR, PW SNR, PW SR

Input trigger pulse setting at 1P SNR and 1P SR

Input trigger pulse : positive polarity

Input trigger pulse : negative polarity

Exposure time setting at 1P SNR and 1P SR

0.01ms0.02 ms 0.4 ms 1 ms20 ms50 ms

0.01 ms

0.02 ms

0.1 ms

1 ms

2 ms

step

step

step

step

step

Partial scanning switch OFF/25fps/30fps/35fps/40fps/45fps/50fps/ E25fps/E30fps/E35fps/E40fps/E45fps/E50fps

(a) Changing the polarity of inputting trigger pulse setting

1Set the "" to TRG.P by pushing [MENU UP], [MENU DOWN] buttons.

2Select either , by pushing [DATA UP], [DATA DOWN] buttons.

(b) Changing 1P SR exposure time setting

1Set the "" to EXP. by pushing [MENU UP], [MENU DOWN] buttons.

2Set the exposure time by pushing [DATA UP], [DATA DOWN] buttons.

(c) Changing the partial scanning setting

1Set the "" to PART by pushing [MENU UP], [MENU DOWN] buttons.

2Select the mode by pushing [DATA UP], [DATA DOWN] buttons.

16

Page 16
Image 16
Toshiba IK-TF9U Changing each setting in 1P SR mode, Mode = E.TRG E.TRG = 1P SR, 1P SNR, 1P SR, PW SNR, PW SR