User’s Manual 69
2. Expanded Functions
Ethernet
IP address = 133.113.98.10
T3H T3H
(self-station) (target-station)
F5000 D4000
F5001 D4001
F5199 D4199
When R0030 is ON, 200 words data starting with D4000 of the T3H on which EN311 (IP address =
133.113.98.10) is installed, is read and stored in F5000 and after.
When the operation is completed, the status is set in RW060 and instruction output com es ON.
Note
Keep the input ON until the output comes ON.
This instruction becomes error complete in the following cases. (ERF = S0051 is set to ON)
(1) Target station No. is invalid. (for S20LP)
(2) Invalid register designation. (In case of T and C registers, T T and C C is only possible)
(3) Source/destination register address range is out of valid range.
(4) Destination register is write-protected.
(5) Response time-out is occurred.
(6) If expanded F register is designated;
- when MMR setting is not made.
- when IC card is not installed.
- when IC card is used to store program .
- when IC card is write-protected. (for destination)
By using SW067, self-station’s register write-protect is available.
F 9 8 7 6 5 4 3 2 1 0
SW067 SW C T F D RW LW W YW
0: Write enable
1: Write protect
Resetting the status register (operand B) is necessary at the first scan.
When using the TOSLINE-S20LP or Ethernet module (EN311), read the manual for these network
modules.
Both F register in CPU and
expanded F register in IC card