Maintenance List

Concealed Duct High Static Pressure

Installation Manual

 

Maintenance List

Part

Unit

 

Check (visual/auditory)

Maintenance

 

 

 

 

Heat exchanger

Indoor/outdoor

• Dust/dirt clogging, scratches

• Wash the heat exchanger when it is

 

 

clogged.

 

 

 

 

 

 

 

 

Fan motor

Indoor/outdoor

• Sound

• Take appropriate measures when

 

 

abnormal sound is generated.

 

 

 

 

 

 

 

 

 

 

• Dust/dirt, breakage

• Wash the filter with water when it is

Filter

Indoor

 

 

contaminated.

 

 

 

 

• Replace it when it is damaged.

 

 

 

 

 

 

• Vibration, balance

• Replace the fan when vibration or balance

Fan

Indoor

Dust/dirt, appearance

is terrible.

 

 

• Brush or wash the fan when it is

 

 

 

 

 

 

 

 

contaminated.

 

 

 

 

Air inlet/outlet grilles

Indoor/outdoor

• Dust/dirt, scratches

• Fix or replace them when they are

 

 

deformed or damaged.

 

 

 

 

 

 

 

 

Drain pan

Indoor

• Dust/dirt clogging, drain

• Clean the drain pan and check the

 

contamination

downward slope for smooth drainage.

 

 

 

 

 

 

 

Ornamental panel,

Indoor

• Dust/dirt, scratches

• Wash them when they are contaminated or

louvres

 

 

apply repair coating.

 

 

 

 

 

 

 

Exterior

Outdoor

• Rust, peeling of insulator

• Apply repair coating.

Peeling/lift of coat

 

 

 

 

 

 

 

 

 