11. PROGRAMMING PROCEDURES

11.16 TRANSFERRING LOGO DATA

11.16 TRANSFERRING LOGO DATA

In ESB Limited Spec. Mode, this programming is unavailable.

Menu Group: 2

Item No.:8

Logo data is created on a PC and stored into RAM through the CMT interface. Two different sizes of logos, 320x118 dots and 256x64 dots, are available on the SL-9000 series. 64KB of RAM area is secured for logo data, in which the maximum of 13 logos (320x118 dots) or 26 logos (256x64 dots) can be stored. Before starting the following operation, set the initial setting #10-7 to 1.

<MENU>

Group 2

 

 

 

 

Select a transmission item.

8

Load the tape into

1: SAVE(SL-9000

CMT)

 

the CMT Loader

2:VERIFY(SL-9000=CMT)

 

 

 

 

 

 

3:LOAD(SL-9000

CMT)

 

ENTER

PROG. <MENU>

 

 

 

 

Group 2

 

 

 

 

ESC.

Main

 

 

 

 

<MENU>

 

 

 

 

 

NOTE: Two sizes of logos are printed differently as follows:

<Label><Receipt>

320x118-dot size logo

256x64-dot size logo

The logo is printed at the lower

A whole Logo #1 and a half of

center of the print area.

logo #2 area printed.

: Print area for logo

: Logo

Table 6: Error message during data transmission

 

Error position

Error message

Cause

 

Header text Data text

TIME OUT ERROR

Timeout

 

Incorrect segment

 

Incorrect logo size

 

Incorrect number of logos

DATA ERROR

Incorrect logo number

 

Incorrect number of dots to be printed.

 

Parity error

 

Framing error

 

Overrun error

11-28

Page 54
Image 54
Toshiba SL-9000-ESB SERIES, EM1-31074EE Transferring Logo Data, Error message during data transmission, Time OUT Error