Installer’s Guide
RETURN AIR FILTERS FOR UPFLOW FURNACE IN HORIZONTAL CONFIGURATION
When the Upflow Furnace is installed in a horizontal configu- ration, the filter must never be installed inside or outside the cabinet directly above the blower assembly. See Figure 11 (page 9). Remote filter grilles may be used for homeowner convenience or the filters may be installed in the duct work upstream of the furnace. See Figures 11 (page 9) and 21 (page 11).
ALTERNATE UPFLOW
FILTER CLIP / BRACKET INSTALLATION - KIT09224
1.Determine the location to be used. The furnace cabinet has dimples for location of the alternate furnace clips (Side return only).
2.Install the clips in front and rear of the desired location using the screws provided. The filter clip with the leaf spring mounts in the rear of the cabinet. See Figure 22.
s
REAR
SIDE | |
- | OUT |
CUT |
|
ALTERNATE FILTER
CLIPS LOCATION
Optional horizontal filter conversion kits are BAYFLTR203 for 17 1/2" width cabinets, BAYFLTR204 for 21" width cabinets, and BAYFLTR205 for 24" width cabinets. These include filters and brackets necessary for horizontal filters. In addition, optional door kit BAYFLTR206 is also available. See Figures 21 and 24.
INSTALLING THE OPTIONAL FILTER
The filter may need to be cut to fit the unit depending on the location of the return air filter.
A score line and the words “CUT HERE” are located on the end of the filter. If your application requires cutting the filter, do so as indicted by the score mark.
TABLE 6
UNIT | RETURN AIR | |
|
| |
SIZE | BOTTOM | SIDE |
|
|
|
CUT ON LINE | DO NOT CUT | |
|
|
|
DO NOT CUT | DO NOT CUT | |
|
|
|
21" | DO NOT CUT | CUT ON LINE |
|
|
|
DO NOT CUT | CUT ON LINE | |
|
|
|
TYPICAL DOWNFLOW FURNACE
RETURN AIR FILTER INSTALLATIONS
di
Airflow
f
Airflow
Optional door kit
BAYFLTR206
Two high velocity type air filters are required for each down- flow furnace. Downflow furnace filters must be located outside the furnace cabinet. Typical installations are shown in Figures 23 and 24. Tables 7 and 8 (page 13) provide information for installation of the filter retaining brackets shipped with downflow furnaces.
TABLE 7
CABINET | FILTER | FILTER BRACKET |
WIDTH | SIZE | LOCATION * |
|
|
|
2 - 14X20X1 | ||
2 - 16X20X1 | ||
21" | 2 - 16X20X1 | |
2 - 16X20X1 |
* Location dimension is from end of duct to the screw holes for the bracket.
TABLE 8
CABINET | RETURN | FILTER ACCESS | FILTER ACCESS | |
DUCT | OPENING - | OPENING - | ||
WIDTH | ||||
WIDTH | DIMENSION "A" | DIMENSION "B" | ||
| ||||
|
|
|
| |
12" | 14" | |||
15" | 14" | |||
21" | 14" | |||
22" | 14" |
14 |