Trane DX1C100A9481A manual Installer’s Guide, Integrated Furnace Control Error Flash Codes

Models: UX1D100A9601A DX1B060A9361A UX1D120A9601A DX1B080A9421A DX1B040A9241A DX1C100A9481A DX1D120A9601A UX1B040A9241A UX1B060A9241A UX1B060A9361A UX1B080A9241A UX1B080A9421A UX1C100A9361A UX1C080A9601A UX1C100A9481A

1 40
Download 40 pages 62.41 Kb
Page 39
Image 39
INTEGRATED FURNACE CONTROL ERROR FLASH CODES

Installer’s Guide

INTEGRATED FURNACE CONTROL ERROR FLASH CODES

Flashing Slow ---

Normal - No call for Heat

Flashing Fast ---

Normal - Call for Heat

Continuous ON ---

Replace IFC

Continuous OFF ---

Check Power

2 Flashes ---

System Lockout (Retries or Recycles exceeded)

 

Draft Pressure Error - Possible problems:

3 Flashes ---

a) Venting problem

b) Pressure switch problem

 

 

c) Inducer problem

4 Flashes ---

Open Temperature Limit Circuit

5 Flashes ---

Flame sensed when no flame should be present

6 Flashes ---

115 volt AC power reversed, poor grounding or system voltage too low

7 Flashes ---

Gas valve circuit error

8 Flashes ---

Low flame sense signal

9 Flashes ---

Check Ignitor Circuit and Line "N" to 24VAC "Common" voltage (2 volts)

[possible grounding problem]

 

18-CD19D6-32

39

Page 39
Image 39
Trane DX1C100A9481A, UX1C100A9481A, UX1C080A9601A manual Installer’s Guide, Integrated Furnace Control Error Flash Codes