Trane UX1B080A9421A Installer’s Guide Contents, Installation Instructions, Abnormal Conditions

Models: UX1D100A9601A DX1B060A9361A UX1D120A9601A DX1B080A9421A DX1B040A9241A DX1C100A9481A DX1D120A9601A UX1B040A9241A UX1B060A9241A UX1B060A9361A UX1B080A9241A UX1B080A9421A UX1C100A9361A UX1C080A9601A UX1C100A9481A

1 40
Download 40 pages 62.41 Kb
Page 3
Image 3
FIRE OR EXPLOSION HAZARD

Safety signal words are used to designate a degree or level of seriousness associated with a particular hazard. The signal words for safety markings are WARNING and

CAUTION.

a. WARNING indicates a potentially hazardous situa- tion which, if not avoided, could result in death or serious injury.

b.CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or mod- erate injury. It is also used to alert against unsafe practices and hazards involving only property dam- age.

! WARNING

FIRE OR EXPLOSION HAZARD

Failure to follow the safety warnings exactly could re- sult in serious injury, death or property damage. Improper servicing could result in dangerous opera- tion, serious injury, death, or property damage.

GENERAL INSTALLATION INSTRUCTIONS

The manufacturer assumes no responsibility for equip- ment installed in violation of any code or regulation.

It is recommended that Manual J of the Air Condition- ing Contractors Association (ACCA) or A.R.I. 230 be fol- lowed in estimating heating requirements. When esti- mating heating requirements for installation at alti- tudes above 2000 ft., remember the gas input may need to be reduced (See High Altitude Installation).

Material in this shipment has been inspected at the factory and released to the transportation agency without known damage. Inspect exterior of carton for evidence of rough handling in ship- ment. Unpack carefully after moving equipment to approximate location. If damage to contents is found, report the damage immediately to the de- livering agency.

Codes and local utility requirements governing the installation of gas fired equipment, wiring, plumbing, and flue connections must be adhered to. In the ab- sence of local codes, the installation must conform with latest edition of the National Fuel Gas Code ANSI Z223.1 • National Installation Code, CAN/CGA B149.1. The latest code may be obtained from the American Gas Association Laboratories, 400 N. Capitol St. NW, Washington D.C. 20001.

1-800-699-9277 or www.aga.org

These furnaces have been classified as CATEGORY IV furnaces in accordance with latest edition of ANSI Z21.47 • CAN/ CGA 2.3 standards.

Installer’s Guide Contents

INSTALLATION INSTRUCTIONS

General Installation Instructions

3

 

 

Location and Clearances

4

 

 

Outline Drawings

5

 

 

Upflow Installation

7

 

 

 

Downflow

Installation

7

 

 

 

Horizontal

Installation

7

 

 

Air For Combustion and Ventilation

8

 

 

Duct Connections

10

 

 

Return Air Filters

11

 

 

General Venting Instructions

15

 

 

Venting Material

16

 

 

Venting Tables

17-19

 

 

Horizontal Venting

20

 

 

Venting Through The Wall

20

 

 

Venting Through The Roof

23

 

 

Downward Venting

23

 

 

Venting Through a Masonry Chimney

23

 

 

Condensate Drain Instructions

26

 

 

 

Electrical

Connections

29

 

 

Field Wiring Diagrams

28-30

 

 

Gas Piping

31

 

 

Combustion Input Checks

32

Start Up and Adjustment

35

 

 

Preliminary Inspections

35

 

 

Lighting Instructions

35

 

 

Sequence Of Operation

36

 

 

Control And Safety Switch Adjustments

36

 

 

Airflow Adjustment

36

Abnormal Conditions

37

 

 

IFC Error Flash Code

39

 

 

 

 

Category IV furnaces operate with positive vent static pressure and with a flue loss less than 17 percent. These conditions require special venting systems, which must be gas tight and water tight. These Category IV Direct Vent furnaces are approved for installation in Manufactured/ Mobile housing when used with BAYMFGH100A.

18-CD19D6-32

3

Page 3
Image 3
Trane UX1B080A9421A Installer’s Guide Contents, Installation Instructions, Start Up and Adjustment, Abnormal Conditions