Trane UX1B040A9241A Installer’s Guide, BAYAIR30AVENTA, BAYVENT200B, AT A MAXIMUM OF 3 INTERVALS

Models: UX1D100A9601A DX1B060A9361A UX1D120A9601A DX1B080A9421A DX1B040A9241A DX1C100A9481A DX1D120A9601A UX1B040A9241A UX1B060A9241A UX1B060A9361A UX1B080A9241A UX1B080A9421A UX1C100A9361A UX1C080A9601A UX1C100A9481A

1 40
Download 40 pages 62.41 Kb
Page 22
Image 22
NOTE: VENT AND INLET MUST BE SUPPORTED

Installer’s Guide

v

COMBUSTION

AIR INLET

40" UPFLOW OR DOWNFLOW MODELS

AT A MAXIMUM OF 3' INTERVALS SEE VENTING TABLE BAYAIR30AVENTA

STRAPS OR OTHER SUITABLE SUPPORTS AT MAXIMUM OF 3'-0" INTERVALS

UPWARD PITCH -- 1/4" PER FOOT

FIRST SUPPORT SHOULD BE AS

CLOSE TO FURNACE CONNECTION

AS POSSIBLE.

NOTE: ANY FITTINGS PASSING

THROUGH AN UNHEATED SPACE

MUST BE INSULATED.

NOTE: VENT AND INLET MUST BE SUPPORTED

AT A MAXIMUM OF 3' INTERVALS

USE ONLY

APPROVED

TERMINATION

OUTSIDE

WALL

STRAP (FIELD SUPPLIED)

TEE

COMBUSTION

REDUCING

AIR

COUPLING,

 

RAIN CAP

FIELD SUPPLIED

IF NEEDED

 

VENT

COMBUSTION AIR

BAYAIR30AVENTA

ELBOW (FIELD SUPPLIED)

VENT

 

2", 2-1/2"

 

or 3" PIPING

 

1" + 1/2"

 

 

3" PIPING

BAYVENT200B

SEAL ALL

WALL CAVITIES

22

18-CD19D6-32

Page 22
Image 22
Trane UX1B040A9241A, UX1C100A9481A Installer’s Guide, BAYAIR30AVENTA, BAYVENT200B, Note Vent And Inlet Must Be Supported