Trane DX1C100A9481A manual Installer’s Guide, The single wall flue pipe joints must be sealed

Models: UX1D100A9601A DX1B060A9361A UX1D120A9601A DX1B080A9421A DX1B040A9241A DX1C100A9481A DX1D120A9601A UX1B040A9241A UX1B060A9241A UX1B060A9361A UX1B080A9241A UX1B080A9421A UX1C100A9361A UX1C080A9601A UX1C100A9481A

1 40
Download 40 pages 62.41 Kb
Page 24
Image 24
TYPE 29-4C STAINLESS STEEL VENTING -

Installer’s Guide

.

/

TYPE 29-4C STAINLESS STEEL VENTING -

USED THROUGH CHIMNEY THAT VENTS

 

ANOTHER GAS APPLIANCE

 

STAINLESSSTAINLESSSTEEL

 

 

VENTSTEELCAP

 

 

VENT CAP

 

 

(OPTIONAL)

 

SEE CAUTION

6 IN. MIN.

 

 

SUPPORT THE SINGLE WAL

!SEAL BETWEEN FLANGE, PIPE, COUPLING AND METAL PANEL

WITH HI TEMP RTV SILICONE SEALANT

FLUE PIPE

COUPLING

SUPPORT

FLANGE

CEILING

GALVANIZED FIRESTOP SHOULD

BE FABRICATED WITH 3-7/8" DIA.

HOLE FOR SUPPORT FLANGE (12" x 12" PANEL OR 12" DIA MIN.)

CLEARANCE ( 0" ACCEPTABLE FOR PVC VENT PIPE )

( 1" ACCEPTABLE FOR TYPE 29-4C STAINLESS STEEL VENT PIPE )

VENTING THROUGH CEILING

@PVC PLASTIC VENTING - ONLY THROUGH UNUSED CHIMNEY

STAINLESS STEEL

VENTCAP

(OPTIONAL)

SEE CAUTION

6 IN. MIN.

STAINLESS STEEL GAS VENTING AND CENTER IT IN THE CHIMNEY OPENING WI ANGLES AS SHOWN OR ANOTHER EQUIVALENT MANNER.

FLUE PIPE

OUPLING TO SUPPORT PE FROM ANGLES

R OTHER SUITABLE UPPORT METHOD

SUPPORT THE SINGLE WALL FLUE PIPE AND CENTER IT IN THE CHIMNEY OPENING WI ANGLES AS SHOWN O ANOTHER EQUIVALEN MANNER.

COUPLING

AS REQUIRED

NOTE:

HORIZONTAL VENTING

TO VERTICAL VENTING

! CAUTION

Do NOT run vent through chimney for wood burn- ing or oil furnaces or incinerators.

If remaining free area between single wall flue pipe and masonry chimney is to be used for another gas appliance venting area must be sufficient to vent that appliance and that appliance must be con- nected to chimney with separate entry openings.

IMPORTANT

The single wall flue pipe joints must be sealed.

The 90° elbow connection to vertical pipe must be sealed to prevent condensate leakage to base of ma- sonry chimney.

FLUE PIPE

NOTE:

HORIZONTAL VENTING

TO VERTICAL VENTING

! CAUTION

Do NOT run vent through chimney for wood burning or oil furnaces or incinerators or any other gas appliance.

IMPORTANT –
The single wall flue pipe joints must be sealed.

The 90° elbow connection to vertical pipe must be sealed to prevent condensate leakage to base of masonry chimney.