IMPORTANT:

The Commonwealth of Massachusetts requires compliance with regulation 248 CMR 4.00 and 5.00 for installation of through – the – wall vented gas appliances as follows:

For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:

1.INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back- up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors

a.In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.

b.In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.

2.APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.

3.SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”.

Installer’s Guide

4.INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4.

This appliance requires a special venting system. If BAYAIR30AVENTA or BAYVENT200B are used, a copy of the installation instructions for the kit shall remain with the appliance or equipment at the completion of installation. The venting system installation instructions can be obtained from the manufacturer by writing to the following address:

American Standard, Inc.

6200 Troup Highway

Tyler, TX 75707

Attention: Manager of Field Operations Excellence

18-CD19D6-32

25

Page 25
Image 25
Trane DX1B040A9241A, UX1C100A9481A, UX1C080A9601A, UX1C100A9361A, UX1B080A9421A, UX1B080A9241A, UX1B060A9361A Installer’s Guide

UX1D100A9601A, DX1B060A9361A, UX1D120A9601A, DX1B080A9421A, DX1B040A9241A specifications

The Trane UX1B040A9241A, DX1D120A9601A, UX1D120A9601A, UX1B060A9241A, and DX1C100A9481A are part of Trane's innovative line of HVAC systems, designed to provide efficient heating and cooling for both residential and commercial applications. Each model is equipped with state-of-the-art features and technologies that prioritize energy efficiency, durable performance, and innovative climate control solutions.

The UX1B040A9241A is a top-performing air conditioning unit that incorporates Trane's advanced variable-speed compressor technology. This allows for precise temperature control and consistent comfort while minimizing energy consumption. The system is also known for its quiet operation, making it ideal for residential settings where noise may be a concern.

On the other hand, the DX1D120A9601A model is particularly notable for its high energy efficiency ratings, incorporating a two-stage cooling system that enhances performance even in extreme weather conditions. This unit is engineered with a durable cabinet and a dependable design to stand up to harsh outdoor environments while providing reliable indoor comfort.

The UX1D120A9601A shares many of the same benefits, offering a flexible multi-stage system that can adapt to varying cooling loads. Its compact design allows for easy installation and maintenance, providing owners with versatility in placement and user-friendly servicing options.

The UX1B060A9241A model balances high performance with eco-friendly operation. It features advanced refrigerant technology that is compliant with today's environmental standards while maintaining high-efficiency ratings. This model ensures consistent comfort without sacrificing environmental responsibility.

Meanwhile, the DX1C100A9481A introduces a simplified yet effective approach to heating and cooling. This unit is designed for easy installation and offers user-friendly controls that allow homeowners to effortlessly adjust settings for optimal comfort throughout the year.

Overall, these Trane models come equipped with robust warranties, ensuring that customers have peace of mind with their investment. Their combination of innovative technology, energy efficiency, and reliability establishes Trane as a trusted choice for climate control solutions. Whether for residential or commercial needs, these models deliver quality performance that meets the demands of their users.