Digit 1 - Unit Function

W = Packaged Heat Pump

Digit 2 - Efficiency

S = Standard Efficiency

Digit 3 - Airflow

C = Convertible

Digits 4,5,6 - Nominal Gross Cooling Capacity (MBh)

 

 

kW

Tons

060

=

17.6

5

072

=

21.1

6

090

=

26.4

7.5

120

=

35.1

10

Digit 7 - Major Design Sequence

A = First

Digit 8 - Unit Voltage

D = 380–415/50/3

T = 200/50/3

Digit 9 - Unit Controls

R = ReliaTelMicroprocessor

Digit 10 - Electric Heater

0 = No Electric Heater

Digit 11 - Minor Design Sequence

A = First Sequence

Digits 12,13 - Service Sequence

**= Factory Assigned

Digit 14 - Fresh Air Selection

0 = No Fresh Air

A = Manual Outside Air Damper 0-50%

B = Motorized Outside Air Damper 0-50% C = Economizer, Dry Bulb 0-100% without

Barometric Relief

D = Economizer, Dry Bulb 0-100% with Barometric Relief

E = Economizer, Reference Enthalpy 0-100% without Barometric Relief F = Economizer, Reference Enthalpy

0-100% with Barometric Relief

G = Economizer, Comparative Enthalpy 0-100% without Barometric Relief

H = Economizer, Comparative Enthalpy 0-100% with Barometric Relief

Digit 15 - Supply Fan/Drive Type/Motor

0 = Standard Drive

1 = Oversized Motor

Digit 16 - Hinged Service Access/Filters

0 = Standard Panels/Standard Filters

A = Hinged Access Panels/Standard Filters

B = Standard Panels/50mm (2”) Pleated

Filters

C = Hinged Access Panels/50mm (2”)

Pleated Filters

Digit 17 - Condenser Coil Protection

0 = Standard Coil

1= Standard Coil with Hail Guard

2= Epoxy Coated Condenser Coil

3= Epoxy Coated Condenser Coil with Hail Guard

Digit18 - Through the Base Provisions

0 = No Through the Base Provisions

Digit 19 - Disconnect/Circuit Breaker/Phase Monitor (3 phase only)

0 = No Disconnect or Circuit Breaker

3 = Phase Monitor Only (No Disconnect, No Circuit Breaker)

Digit 20 - Convenience Outlet

0 = No Convenience Outlet

Digit 21 - Communications Options

0 = No Communications Interface

1 = Comm-3/4 Trane Communications

Interface

2 = Comm-5 LonTalk Communications

Interface

Digit 22 - Refrigeration System Option

0 = Standard Refrigeration System

Digit 23 - Refrigeration Controls

0 = No Refrigeration Control

Digit 24 - Smoke Detector

0 = No Smoke Detector

Digit 25 - Monitoring Controls

0 = No Monitoring Control

1= Clogged Filter Switch

2= Fan Failure Switch

3= Discharge Air Sensing Tube

4= Clogged Filter Switch and Fan Fail Switch

5= Clogged Filter Switch and Discharge Air Sensing Tube

6= Fan Fail Switch and Discharge Air Sensing Tube

7= Clogged Filter and Fan Fail Switches and Discharge Air Sensing Tube

12

PKGP-PRC004-EN

Page 12
Image 12
Trane WSC060-120 manual Model Number Description, 060 11 12,13