Configuration Remote Unit Configuration
Trango Broadband Wireless — TrangoLINK-45 page 21
2. Set the Peer ID with the MAC address of the RU. Only use the last 8 digits of the MAC address.
#> peerid de1B7850
Success.
#>
3. Set channel and polarization. (in this example set the channel to 2 and polarization to H).
#> freq 2 h
Ch# 23 h (5280 MHz)
Success.
4. Set default Opmode to ON.
#> defaultopmode on
Success.
5. Reboot the radio
#> reboot
(NOTE: It is critical to reboot after the utype has been changed before turning Opmode “On”)
After the radio reboots, start another telnet session with the radio and proceed as follows:.
1. Turn Opmode ON.
#> opmode on
Success.
.
Remote Unit Configuration
Configure the RU in the same manner as the MU. Since the default unit type (utype) is RU, you do not need to set this
parameter.
1. Set the Peer ID with the MAC address of the MU. Only use the last 8 digits of the MAC address.
#> peerid de1B7842
Success.
#>
2. Set channel and polarization. (in this example set the channel to 2 and polarization to H).
#> freq 2 h
Ch# 2 h (5280 MHz)
Success.
3. Set default Opmode to “ON.”
#> defaultopmode on
Success.
4. Reboot the radio
#> reboot
(NOTE: It is critical to reboot after the utype has been changed before turning Opmode “On”)
After the radio reboots, start another telnet session with the radio and proceed as follows:.
1. Turn Opmode ON.
#> opmode on
Success.