6. Maintenance

6.2Fuses The circuit breaker (thermal fuses) for MultiTemp III are loca- ted on the rear of the unit.

Note: If the circuit breaker has been triggered, there may be some delay before it can be released. Please push the circuit breaker button only; do not pull.

Manual background PUSH

Ratings for the circuit breaker:

for 198 to 253 V version

two circuit breakers

2 x 8 Amps

for 95 to 132 V version

one circuit breaker

1 x 13 Amps

Fuses for the electronics located inside the unit must be repla- ced by authorised personnel only:

for 198 to 253 V version

fuse

1 x 40 mAmps/T

for 95 to 132 V version

fuse

1 x 63 mAmps/T