DR + GPS
STARTER KIT REFERENCE MANUAL
Lassen DR + GPS Reference Manual 64
Table 31: 0x14-01: Soft event log entry report
Byte Name Type Value Meaning
Code U8 0x14
Subcode U8 0x01 Parameter subcode
Index U8 0
[1,127]
Most recent soft event
Soft Event Log index number
0-1 Year U16 0
>2000
No GPS/UTC; time is since power-up
year
2 Month U8 [1, 12]
3 Day U8 [1, 31]
4 Hour U8 [0, 23]
5 Minute U8 [0, 59]
6 Second U8 [0, 60]
7 Identity Code U8 0xFF
0-0x7F
No event
8 Condition Code U8
0x14-02: Fatal Error Log Report
On a fatal error, the receiver will reset. The report can be queried by index
number after the reset. Because of the volume of information, these reports
cannot be queried with the “0xFF” option. The fatal error log is retained in flash
and cannot be cleared by the host.
Table 32: 0x14-02: Fatal error log entry report
Byte Name Type Value Meaning
Code U8 0x14
Subcode U8 0x02 Parameter subcode
Index U8 0
[1, 31]
Most recent fatal error
Fatal error Log index number
0 Year U16 0
>2000
No GPS/UTC; time is since power-up
year
2 Month U8 [1, 12]
3 Day U8 [1, 31]
4 Hour U8 [0, 23]
5 Minute U8 [0, 59]
6 Second U8 [0, 60]
7 Event Code U16 0
>0
No entry.
Event Code
9 – 30 Info block