DR + GPS
STARTER KIT REFERENCE MANUAL
Lassen DR + GPS Reference Manual 84
0x2F-04: Gyro Bench Test Interval Control
The module can bench-test gyro performance. This test is similar to the gyro part
of the power-up ADC/gyro test. The test starts immediately upon receipt of the
set command for 2F-04. When the test is finished, it automatically reports
message 3F-04. The unit must be stationary for this test to be meaningful. This
message cannot be queried.
There are two modes possible: automatic and manual. Automatic-control mode
sets the Time Interval between one and 60 seconds. The test begins immediately
upon receipt of the set command and lasts until the end of the time interval.
Manual-control mode uses the set command with the Time Interval Data field set
to a large number (e.g., 60) and then issuing an “Stop Immediately” command
when desired. If a test is currently running, this command will return an
acknowledgment “contradicts current data”.
Table 57: 0x2F-04: Gyro Bench Test Interval Report Message
Byte Name Type Value Meaning
Code U8 0x2F
Subcode U8 0x04
0-1 Time Interval U16 0
[1, 60]
Stop Immediately
Perform test for this interval (seconds)