DR + GPS
STARTER KIT REFERENCE MANUAL
Lassen DR + GPS Reference Manual 67
0x16-02: Repeat Start-Up Report with System Time
This report is a copy of the start-up message. The first two bytes show the error
code associated with the previous shutdown. The second two bytes indicate
health of the RTC and RAM. The system time is the number of milliseconds since
power-up.
Table 35: 0x16-02: Repeat Start-Up with System Time Message
Byte Name Type Value Meaning
Code U8 0x16
Subcode U8 0x02 Parameter Subcode
0-1 Error Code U16 0
other
Normal shutdown (SW or power)
Abnormal shutdown (Error! Reference
source not found.)
2 Status U8 Reserved
3 0 RAM Signature U1 1 = BBRAM signature valid
3 1 Gyro / ADC test U1 1 = ADC or Gyro self-test error
3 2 RTC Valid U1 1 = RTC valid at startup
3 3 Flash BBRAM U1 1 = BBRAM loaded from Flash
4 Soft Event Index U7 0
[1,127]
No soft event in log at start-up
Last soft event index in log at start-up
5-8 SysClock U32 1 ms System Time