DR + GPS
STARTER KIT REFERENCE MANUAL
Lassen DR + GPS Reference Manual 80
Table 50: Automatic Output Event Trigger Report Message
Byte Name Type Value Meaning
Code U8 0x2A Event Control
Subcode U8 0x00-7F Parser Code
Index U8 0x00-7F
0xFF
Parser Subcode
All subcodes
0 1 Event 1 U1 Almanac Page Collected
0 2 Event 2 U1 Ephemeris Page Collected
0 3 Event 3 U1 Ionosphere-UTC Page Collected
0 6 Event 6 U1 Almanac Health page Collected
0 7 Event 7 U1 Tacho/Gyro Collected (10 Hz, DR GPS)
1 1 Event 9 U1 GPS Measurement Collected (1 Hz)
1 2 Event 10 U1 Least Squares (LS) Fix generated (1 Hz)
1 3 Event 11 U1 LS Fix not generated
1 4 Event 12 U1 Tracking SV List Updated
2 1 Event 17 U1 Self-test complete (DR GPS)
2 3 Event 19 U1 Receiver status changed
2 4 Event 20 U1 Power-on acknowledge
2 5 Event 21 U1 Start-up complete
2 6 Event 22 U1 Ready to shutdown
3 0 Event 24 U1 DPP Calibrated
3 1 Event 25 U1 Direction Switch Calibrated
3 2 Event 26 U1 Gyro Calibrated
3 4 Event 28 U1 Time status change (time set)
3 5 Event 29 U1 Hard Error
Table 51: Automatic Output Time Interval Trigger Report Message
Byte Name Type Value Units Meaning
Code U8 0x2B Time Interval Control
Subcode U8 0x00-7F Parser Code
Index U8 0x00-7F
0xFF
Parser Subcode
All subcodes
0-3 Threshold U32 1 ms Minimum required
4-7 Trigger U32 0
> 0
1 ms Not used
Trigger value