Symptom

Probable Cause

Corrective Action

Recommended Tools

NO CONTACT HEART RATE 600R, 600U

Control Panel

Defective Cables

Defective Handles

Disconnect 7P6A and 7P6B from control panel. 600U (Page 19) 600R (Page 20). Check continuity between 7P6B and handle mounted heart rate sensor plates of the following:

HRRR and pin 6 of 7P6B HRRL and pin 5 of 7P6B HRLR and pin 2 of 7P6B HRLL and pin 1 of 7P6B

Is there continuity?

If yes – replace computer.

If No- continue to the next step

--------

Perform a contact and continuity check on cable 600 12P, 600 12P coils upper cables and the handle cables.

Are cables OK? If No- Replace defective cables. If Yes- continue on to the next step.

--------

Remove and carefully check all connections to the contact plates.

Reconnect loose connections.

If connections OK – Replace handles.

Multi-meter