Symptom

Probable Cause

Corrective Action

Recommended Tools

NO CONTACT

HEART RATE

750U, 750R

Dirty Sensors

Console Set/

Wiring

Wire Connections

Verify hand pulse sensors are clean.

--------

Set meter for continuity.

Remove Console set.

Check for continuity in both sets of hand pulse sensors between the console set and hand pulse sensor plates.

If continuity is OK – Replace Console set. If no- continue on.

--------

Check wire connections @ handlebar console mast joint

Check connections of wires to hand pulse sensor by removing hand pulse sensor plates.

To remove hand pulse sensor plates carefully pry under one end to free them from the plastic handgrips.

Bad connections? - Reconnect/ Replace bad wires.

Recheck continuity.

Note:

You must pedal at least 30 RPM when performing any voltage test. You may require the assistance of another person when performing voltage checks.

Multi-meter Double sided tape