Symptom

Probable Cause

Corrective Action

Recommended Tools

NO RPM READING 500R, 500U

Control Panel/ RPM Sensor

Defective Cables

Defective RPM Sensor Set

Disconnect 5PA from 5PB. Set meter to check continuity between 2 and 5 of 5PB. (See Page 18)

Turn pedals slowly, check continuity between 2 and 5 of 5PB.

Does continuity change from off to on?

If yes – cables and sensor are good – Replace Control Panel.

If no – Go to Defective RPM Set.

When the sensor is over the pickup, continuity will exist. When sensor is not over pickup, cicuit will be open.

--------

Perform continuity checks on all upper and lower cables.

Replace defective cables.

--------

If cables OK- Replace RPM sensor set.