Symptom | Probable Cause | Corrective Action | Recommended Tools |
NO RPM READING 600R, 600U
Control Panel
Defective Cables
Defective RPM
Sensor Set
•Disconnect 5PA from 5PB. (Page 19- 20).
•Set meter to check continuity between pins 2 and 5 of 5PB
•Turn crank and align the magnet with the sensor
•Is there continuity? If Yes – Replace Control Panel. If No- continue to next step.
•Check continuity of RPM Sensor, when magnet is in alignment with the sensor there should be continuity, when not aligned- no continuity. If it does not respond properly- replace the sensor.
•Check gap on RPM Sensor
•Perform a continuity check on all upper and lower cables.
•No continuity? – Replace defective cable.
•Continuity? – Replace RPM Sensor Set.