Symptom

Probable Cause

Corrective Action

Recommended Tools

HEAVY

RESISTANCE

750U, 750R

Console Set

Defective Cables

Lower control Board/Brake

Remove the console set.

Disconnect the 7 pin connector from the back of the console set.

Pedal.

Resistance normal? Replace console set.

--------

Remove pedal and if 3 piece crank remove crank arm.

Remove right side cover assembly.

Disconnect 7- pin connector from the lower control board.

Pedal.

If resistance is normal- replace cable for console.

--------

Disconnect 3- pin connector from the brake.

Resistance still heavy- Replace brake.

Resistance normal

Check brake cables for cross continuity.

Replace lower control board.

Multi-meter

Support Services 800-883-8783

Mon-Fri 8:30am-5:00pm Central Time Zone

Fax: 636-272-7148

 

 

 

Page 13

Page 15
Image 15
True Fitness 500R, 500U, 600R, 750U, 750R, 600U manual Heavy Resistance