Symptom

Probable Cause

Corrective Action

Recommended Tools

IRREGULAR OR NO DISPLAY 600R, 600U

Control Panel

Control Board

Cables

AC Voltage Output

Generator Output Cable

Probe leads between pin 1 and 2 of 5PB. (Page 19-20)

Pedal unit up to at least 30 RPM.

Is voltage 5 VDC?

If not 5 VDC – replace Control Panel.

--------

Disconnect 6PG from 6PH.

Pedal.

Check DC voltage between pins 2 and 3 for 5 VDC.

No 5 VDC? – Replace Control Board.

-------

Perform continuity checks on all upper and lower cables.

Replace defective cables

--------

Check for AC Voltage between pins 1 and 2 of 3PB, and pins 2 and 3 of 3PB.

Is there AC voltage output in both places?

If yes – replace Control Board.

Check for AC Voltage between pins 1 and 2 of 3PD, and pins 2 and 3 of 3PD.

Is there AC voltage output in both places?

If no – replace Generator.

------

Perform a continuity check on the generator output cable.

If no continuity – replace cable

Multi-meter

Page 8

Support Services 800-883-8783

Mon-Fri 8:30am-5:00pm Central Time Zone

Fax: 636-272-7148

 

 

 

Page 10
Image 10
True Fitness 750R, 500U, 750U, 500R manual Irregular or no Display 600R, 600U