Symptom

Probable Cause

Corrective Action

Recommended Tools

NO RESISTANCE 750U, 750R

Console Set

Defective Cables

Power Resistance

Brake Harness/

Lower Board

Remove console bolts to access 7-pin connector. Do not disconnect console set.

Enter DA (resistance) test mode. (Page 2).

Press + key to force .7 VDC out of panel.

Set meter for DC Volts. Measure between #2 pin and #4 pin at 7- pin connector.

Is .7 VDC present? No- replace console set. If present, continue on.

--------

Remove right mast cover and handlebar.

Measure between the #2and #4 wires at the 7 –pin connector on the lower board.

Is .7 VDC present? No- replace cable for console. If present, continue on.

--------

DO NOT PEDAL.

Set meter for resistance. Disconnect 3- pin connector at the lower control board. Measure resistance between #1 pin and #3 pin.

Resistance should be 10 ohms, +/- 1 ohm.

If less than 10 Ohms- replace power resistance. If resistance checks OK, continue on.

--------

DO NOT PEDAL.

Remove main body cover, set meter for continuity.

Disconnect brake cable from brake and lower board.

Check continuity of all wires in cable.

Check for cross continuity- this would indicate multiple shorts in the cable.

No continuity? Replace Brake cable.

Yes continuity? Replace lower board.

Note:

You must pedal at least 30 RPM when performing any voltage test. You may require the assistance of another person when performing voltage checks.