Test Mode *750 ONLY

Procedure

D

I

A G N O S T I C S

To Enter Diagnostic Mode

Console / Display Output

RPM

Console Key Input

Contact Heart Rate

DA (Resistance)

Exit Diagnostics

Press and hold the “Start” key as you begin pedaling.

Continue pedaling throughout the test.

-------

Press “Enter” key – initiates the second LED function test.

Press “Enter” key again –all LED’s should be on.

--------

Press “Enter” key – RPM’s displayed in the far right window.

--------

Press “Enter” key –A beep should sound when each key is pressed.

--------

Press “Enter” key. Hold both handle pick-ups. Heart symbol will flash and readout will display.

-------

Press “Enter” key – Press + to increase resistance and – to decrease resistance.

To quit diagnostics press “Enter” key or stop pedaling and the unit will reset.

Page 2

Support Services 800-883-8783

Mon-Fri 8:30am-5:00pm Central Time Zone

Fax: 636-272-7148

 

 

 

Page 4
Image 4
True Fitness 750R, 500U, 600R, 750U, 500R, 600U manual N O S T I C S, Rpm