Search and Close Call Options

The settings in this section affect custom searches,
air service search and Close Call operation.
See the teble below showing what options are
available for each of the search modes.

Managing Locked-Out Frequencies

While searching or during Close Call operation, if you
press L/O while the scanner is stopped on a frequency,
that frequency is locked out of these modes. You can
lock out up to 200 frequencies.
Note: Locking out a frequency does not lock out a
channel that contains that frequency.

Unlocking All Frequencies

Srch/CloCall Opt

Freq Lockouts

Unlock All
The scanner prompts you to confirm deletion.
To confirm and delete all locked-out frequencies, press
the scroll control. Otherwise, to cancel, press .

Reviewing Locked Out Frequencies

Srch/CloCall Opt

Freq Lockouts
Setting Item Service
Search*1
Custom
Search *1
Quick
Search
Search
and Store
Close
Call
CC Auto
Store
Freq Lockouts O O O O O O
Broadcast
Screen OO
O*2OO
CTCSS/DCS
Search OOOOO
Max Auto Store O O
Set Delay Time O O
Set Modulation O
Set Attenuator O O O
Set Data Skip O O O
Set Step O
Air Band Step O O O O O O
*1 Valid also for Service Search with Scan and Custom Search with Scan.
*2 Valid only when using Custom Search.
Menu
Menu
Search and Close Call Options