If you experience difficulty while in TrunkTracker™ mode,
try the following steps.
Problem Suggestion
Scannerwon’t track the trunked
system.
1. Maynot be a system which can be tracked by
yourscanner.
2. Missingthe data frequency.
3. Changeto a Type 1 Scanner setup.
ReviewFleet Map Programming on page 56.
Scannerwon’t stop during Scan
Listmode.
1. NoIDs have been programmed.
2. TheIDs you have stored are not active.
Scannerwill not acquire data
channel.
1. Adjustthe squelch for trunking mode.
Seepage 39.
2. Missingthe frequency used for the data
channel.Check your frequency list.
Missingreplies to conversations. 1. Change to a Type 1 Scanner setup.
ReviewFleet Map Programming on page 56.
2. Tryanother Preset Fleet Map or Program
yourown Fleet Map.
3. Checkto see that all of the systems
frequencieshave been entered.
ChannelActivity Indicators are
flashingbut no sound is heard.
1. Maybe a private or telephone
interconnectcall, which are intentionally
blockedby your scanner.
2. TheID in your display is not active.
Scannernot tracking an EDACS
systemproperly.
1. Logicalchannel numbers ( frequencies)
forthe system are not programmed in the correct
order.Check frequency resources and reprogram.
2. Notall frequencies for the system are
programmed.Check frequency resources.
If you still cannot get satisfactory results while using your
scanner or if you want additional information, please call or
write to Uniden Australia PTY Limited.The address
and phone number are listed in the Warranty at the end of
thismanual.
If you have internet access, you can visit
www.uniden.com.au or www.trunktracker.com or
www.bearcat1.com/free.htm for additional information.
77