Installation

Tank Gauge Transmitter

 

 

2.2Mounting the Equipment

The ATT is bolted to the Model 2500 Automatic Tank Gauge head as illustrated in Figure 2-2.It may also be mounted to Endress+Hauser, Sakura, Tokyo-Keiso, Shand & Jurs, and Gauging Systems, Inc. float and tape gauges with the Endress+Hauser adapter shown in the following table.

Part Number

Gauge Adapter Kit

13-05956-102

L&J (Shand & Jurs) 92513, 92514, 92020, 92030

 

 

13-05956-202

Whessoe 2006, 2026, 2036 and L&J (Shand & Jurs) 92006

 

 

Mounting the ATT to the Level Gauge is accomplished in the following manner:

1.Remove the back cover of the Level Gauge.

2.Remove the access cap from the back cover of the Level Gauge.

3.Mount the ATT in place of the access cap, making certain that the word "TOP" cast into the housing lines up with the top of the Level Gauge back cover.

4.Install the Level Gauge back cover with the transmitter in the Level Gauge. Make certain that the slot in the ATT drive coupling engages with the pin on the tape sheave of the Level Gauge.

5.Proceed with field wiring.

Drive coupling

5/16-18 X 1 mounting bolts (4 places) 5/16 split lock washers (4 places)

Transmitter

Back cover

Junction box cover

Integral junction box

 

Back Cover

External enclosure ground

External Ground Lug

connection by installer

 

 

Gauge cover mounting

 

bolts (15 places)

Pin drive

Sprocket Sheave

2500

Automatic Tank Gauge

Figure 2-2: ATT Mounting Diagram

4

Installation and Operations Manual

Page 14
Image 14
Varec 4000 manual Mounting the Equipment, Part Number Gauge Adapter Kit