![](/images/new-backgrounds/1205084/205084203x1.webp)
FDC Retail/Debit Purchasing Card Reference Manual
Testing the TRANZ 460/TRANZport 232 Connection
After connecting the TRANZport as previously outlined, the following TCL code can be used to test the system.
Using the standard recall and edit capabilities of the TRANZ 460, load memory locations 31 and 32 with the following TCL command strings:
031=B1.1GR’B PORT TEST’R13R10*R5+R1*I 032=B1.1GR’A PORT TEST’R13R10*R5+R0*I
To test the TRANZport 232 B port, press the [FUNC/ENTER] key then the
[1]key on the TRANZ 460 terminal. This sends ’B PORT TEST’ to the device connected to the B port at 9600 baud.
To test the A port, press the [FUNC/ENTER] key and then the [2] key on the TRANZ 460. This sends ’A PORT TEST’ to the device connected to the A port at 9600 baud.
When the TRANZ 460 is in the Idle Mode, the TRANZport 232 is connected to the B port.
Specifications
Physical Height: 1.5 in. (38.1 mm) Width: 3.5 in .(88.9 mm) Depth: 4.0 in. (101.6 mm)
Shipping Weight: 1.75 lb (0.8 kg), including cables and power supply
Environmental Operating Temperature: 0o to 40oC (32o to 104oF) Operating Humidity: 20% to 90%, no condensation
Power Voltage: 120 VAC, 60 Hz
240 VAC, 50 Hz; 220 VAC, 50 Hz
200 VAC, 50 Hz
Port Configurations
Terminal Input Port (9-pin D-sub male connector)
pin 1 | RTS |
|
pin 2 | TxD | (from terminal) |
pin 3 | RxD | (to terminal) |
pin 4 | CTS |
|
pin 5 | Signal Gnd | |
pin 6 | RTS | (duplicate) |
pin 7 | DCD |
|
pin 8 | RTS | (duplicate) |
pin 9 | DTR |
|
F - 4 | TRANZ 460 Terminal |