Viking VGBQ3002T1NSS manual Outdoor- Cooking, Installation Requirements, Utility

Models: VGBQ3002T1NSS

1 125
Download 125 pages 40.22 Kb
Page 40
Image 40
•Not applicable for QSC200/300 models

OUTDOOR— COOKING

C4™ Charcoal Ceramic Cooking Capsule &

C4™ Cooker Cart

Installation Requirements

VCQS001

VCQS001

VCQS001

C4™ Cooker

C4™ Cooker

C4™ Cooker

w/QSC200

w/QSC300

w/QSC412

20”W. C4 Cooker Cart

30”W. C4 Cooker Cart

41”W. C4 Cooker Cart

 

 

w/Side Burners

 

 

 

 

UTILITY

 

 

REQUIREMENTS

 

 

 

 

GAS

(41”W. QSC412 models only)

Not applicable for QSC200/300 models

Surface burner rating

Two grated grill burners, each @ 15,000 BTU (4.4 kW) Nat./ 13,500 BTU LP (4.0 kW)

Fixed piping installations*

Check with local gas utility company or with local codes for instructions on installing gas supply lines. All gas connections should be made by a competent technician and in accordance with local codes and or ordinances. In the absence of codes, the installation must comply with the National Fuel Gas Code ANSI Z223.1.

An installer-supplied gas shut- off valve must be installed in an easily accessible location. All installer-supplied parts must conform to local codes.

Must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of that system at test pressures equal to or less than 1/2 psi (3.5 kPa).

Natural gas models

Water column pressure

o Operating pressure—4.0”

WCP

o Supply pressure of 6” – 14”

WCP

o If incoming pressure exceeds 14” WCP, a step-down regulator is required.

Accepts standard residential 1/2” (1.3 cm) ID gas service line; 1/2” (1.3 cm) NPT male with 7/8” (2.2 cm) flare adapter.

o If using a Viking GSH12 flexible hose, remove the 1/2” (1.3 cm) flare adapter and attach hose to the 7/8” (2.2 cm) male flare on the regulator assembly.

LP/propane models

Water column pressure

o Operating pressure—10”

WCP

o Supply pressure of 11” – 14” WCP (for fixed piping installations)

o If incoming pressure exceeds 14” WCP, a step-down regulator is required.

Accepts standard residential 1/2” (1.3 cm) ID gas service line; 1/2” (1.3 cm) NPT male with 3/8” (0.95) flare adapter.

LP/propane tank installations

Water column pressure

o Operating pressure—10”

WCP

o Includes high-capacity hose/regulator assembly for

connection to a standard 5-gal./20-lb. (approx. 12” diameter/18”\H.) LP/propane gas cylinder equipped with a Type 1, QCC-1 connector

The cylinder connection device must be compatible with the Type 1, QCC-1 connector on the outdoor cooking appliance.

The cylinder must be provided with a shut-off valve terminating in an LP/propane gas supply cylinder valve outlet specified.

The cylinder supply system must be arranged for vapor withdrawal and provided with a listed OPD (overfilling prevention device).

ELECTRICAL

Not applicable for QSC200/300 models

9-volt DC battery for electronic ignition (QSC412 model (side burners))

PLUMBING

Not applicable

* For fixed pipe fuel installations, remember to place the installer-supplied gas valve in an accessible location.

Cabinet proximity

The cart can be installed directly adjacent to side cabinets. There is 0” side clearance to non-combustible and combustible surfaces. Maintain a minimum of 6” (15.2 cm) from the back of the unit to allow cooker dome to open fully.

P L A N N I N G A N D D E S I G N G U I D E

R E L E A S E D 1 2 / 1 / 0 7

V I K I N G R A N G E . C O M • 1 - 8 8 8 - V I K I N G 1

© 2 0 0 7 V R C — INFORMATION SUBJECT TO CHANGE

Page 40
Image 40
Viking VGBQ3002T1NSS manual Outdoor- Cooking, Installation Requirements, C4 Charcoal Ceramic Cooking Capsule C4 Cooker Cart