OUTDOOR— COOKING

53”W. Ultra-Premium T-Series/E-Series Gas Grill

Installation Requirements

VGBQ530-4RE1

VGBQ532-3RE1

VGIQ530-4RT/E1

VGIQ532-3RT/E1

T-Series/E-Series

T-Series/E-Series

T-Series/E-Series

T-Series/E-Series

Four-Burner All-Grill

Three-Burner Grill

Four-Burner All-Grill

Three-Burner Grill

 

w/Side Burners

(inc. TruSear™ Burner)

w/Side Burners

(inc. TruSear™ Burner)

UTILITY

REQUIREMENTS

GAS

Fixed piping installations

Check with local gas utility company or with local codes for instructions on installing gas supply lines. All gas connections should be made by a competent technician and in accordance with local codes and or ordinances. In the absence of codes, the installation must comply with the National Fuel Gas Code ANSI Z223.1.

An installer-supplied gas shut- off valve must be installed in an easily accessible location. All installer-supplied parts must conform to local codes.

Must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of that system at test pressures equal to or less than 1/2 psi (3.5 kPa).

Natural gas models

Water column pressure

o Operating pressure—4.0”

WCP

o Supply pressure of 6” – 14”

WCP

o If incoming pressure exceeds 14” WCP, a step-down regulator is required.

Accepts standard residential 1/2” (1.3 cm) ID gas service line; 1/2” (1.3 cm) NPT male with 7/8” (2.2 cm) flare adapter.

o If using a Viking GSH12 flexible hose, remove the 1/2” (1.3 cm) flare adapter and attach hose to the 7/8” (2.2 cm) male flare on the regulator assembly.

LP/propane models

Water column pressure

o Operating pressure—10”

WCP

o Supply pressure of 11” – 14” WCP (for fixed piping installations)

o If incoming pressure exceeds 14” WCP, a step-down regulator is required.

Accepts standard residential 1/2” (1.3 cm) ID gas service line; 1/2” (1.3 cm) NPT male with 3/8” (0.95) flare adapter.

LP/propane tank installations

Water column pressure

o Operating pressure—10”

WCP

Includes high-capacity hose/regulator assembly for connection to a standard 5- gal./20-lb. (approx. 12” diameter/18”H.) LP/propane gas cylinder equipped with a Type 1, QCC-1 connector

o The cylinder connection device must be compatible with the Type 1, QCC-1 connector on the outdoor cooking appliance.

o The cylinder must be provided with a shut-off valve terminating in an LP/propane

gas supply cylinder valve outlet specified.

o The cylinder supply system must be arranged for vapor withdrawal and provided with a listed OPD (overfilling prevention device).

ELECTRICAL

T-Series models

o 9-volt DC battery for electronic ignition (not included?)

o 2’ (61.0 cm) power cord supply cord with 3-prong grounded plug attached to rotisserie

120 VAC/60 Hz

o Rotisserie motor max. amp usage—6.0

E-Series models

o 3’ (91.4 cm) power cord supply cord with 3-prong grounded plug attached to grill

120 VAC/60 Hz

o Grill max. amp usage—3.0 o 2’ (61.0 cm) power cord

supply cord with 3-prong grounded plug attached to rotisserie

120 VAC/60 Hz

o Rotisserie motor max. amp usage—6.0

PLUMBING

• Not applicable

VGBQ530-4RE1

VGBQ532-3RE1

VGIQ530-4RT/E1

VGIQ532-3RT/E1

Burner rating

25,000 BTU (7.3 kW) Nat./22,500 BTU (6.5 kW) LP (T-Series)

 

Standard SS grill burners (each)

 

 

29,000 BTU (7.3 kW) Nat./28,000 BTU (6.5 kW) LP (E-Series)

 

Smoker burner (split standard)

12,500 BTU (3.7 kW) Nat./10,500 BTU (3.1 kW) LP

 

GourmetGlo™ rotisserie burner

15,000 BTU (4.4 kW) Nat./13,500 BTU (4.0 kW) LP

 

Side grill burners (each)

15,000 BTU (4.4 kW) Nat./

 

15,000 BTU (4.4 kW) Nat./

 

13,500 BTU (4.0 kW) LP

 

13,500 BTU (4.0 kW) LP

TruSear infrared burner

 

30,000 BTU (8.8 kW) Nat./LP

30,000 BTU (8.8 kW) Nat./LP

P L A N N I N G A N D D E S I G N G U I D E

 

R E L E A S E D 8 / 5 / 0 8

V I K I N G R A N G E . C O M • 1 - 8 8 8 - V I K I N G 1

© 2 0 0 8 V R C — INFORMATION SUBJECT TO CHANGE

Page 22
Image 22
Viking VGBQ3002T1NSS manual Fixed piping installations