Vixel 335 manual Management, Changing the CLI/Web Password

Models: 335

1 74
Download 74 pages 62.9 Kb
Page 46
Image 46
Changing the CLI/Web Password

Vixel Model 335 Installation & Configuration Guide

CHAPTER 3 Management

 

 

Note: If you do not remember your password, call your customer service representative.

Changing the CLI/Web Password

One password is used to access both the Web Manager and the Command Line Interface. You can change the password through the Command Line Interface (CLI) only. The password must be between 6 and 25 characters in length.

To change the password:

1.Type pw at the prompt.

2.Enter the current password (the default password is password).

3.Enter the new password.

4.Confirm the new password by re-entering it.

A message appears confirming that the password was saved and activated.

>pw

enter current password: ********

enter new password

:

******

re-enter new password :

******

The new password is saved and activated.

Viewing Management, Policy, and Threshold Settings

The Management Agent menu displays the current settings for the switch parameters, switch policies, and thresholding. To view the current Management Agent settings and a complete list of commands, type mc at the prompt. The Management Agent Menu appears.

MANAGEMENT AGENT 00-10-9b-01-0c-dd

 

Product

: Vixel 335 Managed Storage Switch

 

Firmware

: 2.01 (build 79)

 

Hardware

: 3

 

IP address

: 172.16.71.14

 

Netmask

: 255.255.240.0

 

Default gateway

: 172.16.64.1

 

DHCP

: disabled

 

Management URL

: http://172.16.71.14

 

POLICIES:

 

(1)

Smart insertion

: enabled

(2)

Bad zone recovery

: disabled

(3)

No data recovery

: disabled

(4)

LIP F8 recovery

: enabled

(5)

LIP on port bypass

: enabled

(6)

Auto cascade

: enabled

(7)

Bypass at max OS err

: disabled

(8)

Bypass at max CRC err

: disabled

(9)Bypass on clock delta err : disabled

(10)

Bypass on

switch stall

: disabled

(11)

Clear conn on sw stall

: disabled

 

HW I/F:

 

 

 

 

ASIC build number

: 0x0001

(12)

OS error

threshold

: 3

(0x3)

(13)

CRC error

threshold

: 3

(0x3)

(14)

Switch stall threshold

: 65535 (0xFFFF)

(15)

Clk error

thresh (ppm)

: 200 (0xC8)

(16)Clk error prescale (1-16) : 6

(17)Err count thresh (CSecs) : 1000

(18)Bad zone thresh (CSecs) : 500

(19)Bad zone bypass (CSecs) : 10

ACTIONS:

(20)Reset switch

(21)Reset HW

(22)Reset counters

(23)Event log

(24)Fibre Alliance event log

(25)Fibre Alliance event sev : Info