APPENDIX C Event Messages

Vixel Model 335 Installation & Configuration Guide

APPENDIX C Event Messages

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ref

Event

Meaning

 

Action

Severity

 

 

Message

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

132

Zone up then down

The zone state has cycled

 

---

Warning

 

 

 

 

through the “up” and “down”

 

 

 

 

 

 

states several times. Current

 

 

 

 

 

 

zone state (at the time of this

 

 

 

 

 

 

message) is down.

 

 

 

 

 

 

 

 

 

 

 

 

 

133

Zone down then up

The zone state has cycled

 

---

Warning

 

 

 

 

through the “up” and “down”

 

 

 

 

 

 

states several times. Current

 

 

 

 

 

 

zone state (at the time of this

 

 

 

 

 

 

message) is up.

 

 

 

 

 

140

Port inserted

A port was inserted onto the

---

Info

 

 

 

 

zone (after being bypassed).

 

 

 

 

 

 

 

 

 

 

 

141

Port bypassed

A port was bypassed (could not

Check all connections

Info

 

 

 

(LIPF8)

insert) because a LIP(F8) was

for the specified port.

 

 

 

 

 

received at port input. (A

 

 

 

 

 

 

 

LIP(F8) indicates a loop fail-

 

 

 

 

 

 

ure.)

 

 

 

 

 

142

Port bypassed (tx

A port was bypassed because

Contact an authorized

Info

 

 

 

fault)

the switch detected a transmit-

service representative.

 

 

 

 

 

ter fault on the port’s trans-

The transceiver may

 

 

 

 

 

ceiver.

 

need replacing.

 

 

 

 

 

 

 

 

 

 

143

Port bypassed

A port was bypassed (could not

---

Info

 

 

 

(timeout)

insert) because no LIP(F7)s

 

 

 

 

 

 

 

were received after continuous

 

 

 

 

 

 

transmission of LIP(F7)s for

 

 

 

 

 

 

112 milliseconds.

 

 

 

 

 

145

Port bypassed

A port was bypassed for a rea-

---

Info

 

 

 

 

son other than transceiver

 

 

 

 

 

 

 

transmitter fault, invalid

 

 

 

 

 

 

 

response, or manual bypass.

 

 

 

 

 

 

 

 

 

 

 

 

146

Port bypassed then

A port was bypassed, then

 

---

Info

 

 

 

inserted

inserted.

 

 

 

 

 

147

Port inserted then

A port was inserted, then

 

---

Info

 

 

 

bypassed

bypassed.

 

 

 

 

 

 

 

 

 

 

 

 

 

150

Transceiver inserted

A transceiver was inserted.

 

---

Notice

 

 

151

Transceiver removed

A transceiver was removed.

---

Notice

 

 

 

 

 

 

 

 

 

 

160

Management active

Agent is operational.

 

---

Info

 

 

165

Agent task asserted

During normal operations, an

Contact an authorized

Critical

 

 

 

on prev exec cycle

attempt to execute a command

service

 

 

 

 

 

was aborted due to an internal

representative.

 

 

 

 

 

error in the firmware.

 

 

 

 

 

 

 

The switch automatically resets

 

 

 

 

 

 

after the occurrence.

 

 

 

 

 

 

 

 

 

 

 

 

166

Agent machine

A task attempted to execute an

Contact an authorized

Critical

 

 

 

exception on prev

unknown command. The

 

service

 

 

 

 

exec cycle

switch automatically resets

 

representative.

 

 

 

 

 

after the occurrence.

 

 

 

 

 

170

Diagnostic function

A diagnostic setting is miscon-

Check diagnostic set-

Warning

 

 

 

aborted

figured and required a firm-

tings for incompatibili-

 

 

 

 

 

ware override.

 

ties.

 

 

 

 

 

 

 

 

 

 

200

CRC error detected

CRC errors were detected in a

No action required. You

Info

 

 

 

 

frame received on a port.

 

can modify the CRC

 

 

 

 

 

 

 

Error threshold through

 

 

 

 

 

 

 

the Web Manager or

 

 

 

 

 

 

 

CLI interface.

 

 

 

201

CRC error threshold

During the past ten seconds, the

No action required. You

Info

 

 

 

exceeded

number of CRC errors in

 

can modify the Error

 

 

 

 

 

frames received by the specified

Count threshold through

 

 

 

 

 

port exceeded the current

 

the Web Manager or

 

 

 

 

 

threshold value.

 

CLI interface.

 

 

 

 

 

 

 

 

 

 

202

OS Error threshold

During the past ten seconds, the

No action required. You

Info

 

 

 

exceeded

number of OS errors (invalid

can modify the Error

 

 

 

 

 

transmit words, or 8b/10b

 

Count threshold through

 

 

 

 

 

encoding errors) in frames

 

the Web Manager or

 

 

 

 

 

received by the specified port

CLI interface.

 

 

 

 

 

exceeded the current threshold

 

 

 

 

 

 

value.

 

 

 

 

 

 

 

 

 

 

 

 

64

Page 67
Image 67
Vixel manual Vixel Model 335 Installation & Configuration Guide, APPENDIX C Event Messages, Meaning, Action, Severity