Vixel 335 manual APPENDIX C Event Messages, Meaning, Action, Severity

Models: 335

1 74
Download 74 pages 62.9 Kb
Page 66
Image 66
APPENDIX C Event Messages

APPENDIX C Event Messages

The event messages are listed by reference number. Also included are the event descriptions, recommended actions, reference numbers, and the message’s applicable severity level, which are each defined below:

Emergency—immediate action required; system failing

Alert—unrecoverable condition reported; major event in progress

Critical—event failed with possible loss of integrity

Error—condition failed; action required

Warning—failed event occurred; no action required

Notice—configuration error or abnormal event occurred; no action required

Info—event occurred; no action required

Debug—internal message for development (excluded in this list)

Mark—message marker (excluded in this list)

These severity levels can be used to designate which events trigger trap messages. For Vixel Switches, you can also designate the minimum severity level of events to be logged in the Event Log and at which to illuminate the switch’s Fault LED.

Ref

Event

Meaning

Action

Severity

Message

 

 

 

 

 

 

 

 

 

1

Agent up

The switch’s management agent

---

Info

 

 

was up. (This message begins

 

 

 

 

the event log at each session.)

 

 

3

Switch added

The switch was added.

---

Info

 

 

 

 

 

5

Switch reset

The switch was reset.

---

Info

10

Switch loopback

ASIC failed its power on self

Contact an authorized

Alert

 

failure

test (internal test).

service representative.

 

 

 

 

 

 

20

Smart insertion

The Smart Insertion policy is

---

Notice

 

mode on

enabled.

 

 

21

Smart insertion

The Smart Insertion policy is

---

Notice

 

mode off

disabled.

 

 

 

 

 

 

 

22

Switch in switching

The switch is running in switch-

---

Notice

 

mode

ing mode.

 

 

23

Switch in normal

The switch is running in normal

---

Notice

 

mode (switching off)

mode (switching is disabled).

 

 

 

 

 

 

 

100

Fan okay

The state of a switch fan

---

Info

 

 

changed to “okay.”

 

 

101

Fan fault

The state of a switch fan

Replace the fan.

Alert

 

 

changed to “fault.”

 

 

 

 

 

 

 

110

Temperature okay

The switch temperature

---

Info

 

 

changed to “okay.”

 

 

111

Temperature warm

The switch temperature

---

Warning

 

 

changed to “warm.”

 

 

 

 

 

 

 

112

Temperature hot

The switch temperature

Power off the switch and

Alert

 

 

changed to “hot.” A fan may

contact an authorized

 

 

 

have failed or the temperature

service representative.

 

 

 

of the location may be exceed-

 

 

 

 

ing the switch’s environmental

 

 

 

 

requirements.

 

 

120

Power okay

The state of the switch power

---

Info

 

 

supply changed to “okay.”

 

 

 

 

 

 

 

121

Power fault

The state of the switch power

---

Alert

 

 

supply changed to “fault.”

 

 

 

 

 

 

 

63

Page 66
Image 66
Vixel 335 manual APPENDIX C Event Messages, Meaning, Action, Severity